AC/DC Desktop Adapter 5V 20W - Advanced Energy / SL Power / Condor
Optimize your electronic devices with the reliable and medical-grade AC/DC desktop power supply from the ME30 family. Designed for safety, efficiency, and durability, this 5V 20W power adapter is ideal for medical and industrial applications requiring high standards of EMC compliance and long-term performance.
The specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Performance criteria are defined as following: A – Normal performance during and after the test, B – Temporary degradation, self-recoverable, C – Temporary degradation, operator intervention required, D – Permanent damage.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10023127908669,"title":"ME30A0503N01","handle":"me30a0503n01","description":"\u003ch3\u003eAC\/DC Desktop Adapter 5V 20W - Advanced Energy \/ SL Power \/ Condor\u003c\/h3\u003e\n\u003cp\u003eOptimize your electronic devices with the reliable and medical-grade AC\/DC desktop power supply from the ME30 family. Designed for safety, efficiency, and durability, this 5V 20W power adapter is ideal for medical and industrial applications requiring high standards of EMC compliance and long-term performance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ME30A0503N01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-me30a0503n01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMedical-grade power supply meeting UL\/EN\/IEC60601-1-2, 4th edition EMC standards\u003c\/li\u003e\n\u003cli\u003eApproved to EN\/IEC\/UL60601-1, 3rd edition for medical safety\u003c\/li\u003e\n\u003cli\u003eHigh efficiency with \u0026gt;8 years capacitor lifespan and \u0026gt;1,000,000 hours MTBF\u003c\/li\u003e\n\u003cli\u003eIP22 rated enclosure for enhanced protection\u003c\/li\u003e\n\u003cli\u003eClass I and Class II models available with different connector configurations\u003c\/li\u003e\n\u003cli\u003e3-year warranty for reliable long-term operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003cth\u003eLine Regulation\u003c\/th\u003e\n\u003cth\u003eLoad Regulation\u003c\/th\u003e\n\u003cth\u003eOvervoltage Trip Range\u003c\/th\u003e\n\u003cth\u003eConnector Configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503N01\u003c\/td\u003e\n\u003ctd\u003e5.0V\u003c\/td\u003e\n\u003ctd\u003e4.00A\u003c\/td\u003e\n\u003ctd\u003e20W\u003c\/td\u003e\n\u003ctd\u003e75mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e5.75V - 7.75V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0903N01\u003c\/td\u003e\n\u003ctd\u003e9.0V\u003c\/td\u003e\n\u003ctd\u003e3.00A\u003c\/td\u003e\n\u003ctd\u003e27W\u003c\/td\u003e\n\u003ctd\u003e90mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e11.7V - 16.2V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A1203N01\u003c\/td\u003e\n\u003ctd\u003e12.0V\u003c\/td\u003e\n\u003ctd\u003e2.50A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e120mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e14.4V - 16.8V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A1503N01\u003c\/td\u003e\n\u003ctd\u003e15.0V\u003c\/td\u003e\n\u003ctd\u003e2.00A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e150mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e18.0V - 21.0V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A1803N01\u003c\/td\u003e\n\u003ctd\u003e18.0V\u003c\/td\u003e\n\u003ctd\u003e1.67A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e180mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e21.6V - 25.2V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A2403N01\u003c\/td\u003e\n\u003ctd\u003e24.0V\u003c\/td\u003e\n\u003ctd\u003e1.33A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e240mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e28.8V - 33.6V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A4803N01\u003c\/td\u003e\n\u003ctd\u003e48.0V\u003c\/td\u003e\n\u003ctd\u003e0.63A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e480mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e55.0V - 60.0V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Models \u0026amp; Configurations\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eReceptacle\u003c\/th\u003e\n\u003cth\u003eBlade Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503F01\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C14\u003c\/td\u003e\n\u003ctd\u003eCenter positive\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503B01\u003c\/td\u003e\n\u003ctd\u003eWall Plug\u003c\/td\u003e\n\u003ctd\u003eNorth American blades\u003c\/td\u003e\n\u003ctd\u003eOrder blade kit KT-1027K for other blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503C01\u003c\/td\u003e\n\u003ctd\u003eWall Plug\u003c\/td\u003e\n\u003ctd\u003eNorth American blades\u003c\/td\u003e\n\u003ctd\u003eOrder blade kit KT-1027K for other blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503Q01\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C18\u003c\/td\u003e\n\u003ctd\u003eCenter positive\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more details, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-me30a0503n01.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eDisclaimer\u003c\/h3\u003e\n\u003cp\u003eThe specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Performance criteria are defined as following: A – Normal performance during and after the test, B – Temporary degradation, self-recoverable, C – Temporary degradation, operator intervention required, D – Permanent damage.\u003c\/p\u003e","published_at":"2025-08-13T19:12:24+05:30","created_at":"2025-08-13T19:12:24+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["20W","5V","AC","ADVAN-SLPO","Desktop","IMPORT_CSV","WLDM"],"price":276073,"price_min":276073,"price_max":276073,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50615898767677,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ME30A0503N01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ME30A0503N01","public_title":null,"options":["Default Title"],"price":276073,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"ME30A0503N01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/ME30A0503N01_48584431_8c72ddf1.jpg?v=1755092547"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/ME30A0503N01_48584431_8c72ddf1.jpg?v=1755092547","options":["Title"],"media":[{"alt":null,"id":45819957543229,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/ME30A0503N01_48584431_8c72ddf1.jpg?v=1755092547"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/ME30A0503N01_48584431_8c72ddf1.jpg?v=1755092547","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAC\/DC Desktop Adapter 5V 20W - Advanced Energy \/ SL Power \/ Condor\u003c\/h3\u003e\n\u003cp\u003eOptimize your electronic devices with the reliable and medical-grade AC\/DC desktop power supply from the ME30 family. Designed for safety, efficiency, and durability, this 5V 20W power adapter is ideal for medical and industrial applications requiring high standards of EMC compliance and long-term performance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ME30A0503N01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BOX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-me30a0503n01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMedical-grade power supply meeting UL\/EN\/IEC60601-1-2, 4th edition EMC standards\u003c\/li\u003e\n\u003cli\u003eApproved to EN\/IEC\/UL60601-1, 3rd edition for medical safety\u003c\/li\u003e\n\u003cli\u003eHigh efficiency with \u0026gt;8 years capacitor lifespan and \u0026gt;1,000,000 hours MTBF\u003c\/li\u003e\n\u003cli\u003eIP22 rated enclosure for enhanced protection\u003c\/li\u003e\n\u003cli\u003eClass I and Class II models available with different connector configurations\u003c\/li\u003e\n\u003cli\u003e3-year warranty for reliable long-term operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003cth\u003eOutput Current\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003eRipple \u0026amp; Noise\u003c\/th\u003e\n\u003cth\u003eLine Regulation\u003c\/th\u003e\n\u003cth\u003eLoad Regulation\u003c\/th\u003e\n\u003cth\u003eOvervoltage Trip Range\u003c\/th\u003e\n\u003cth\u003eConnector Configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503N01\u003c\/td\u003e\n\u003ctd\u003e5.0V\u003c\/td\u003e\n\u003ctd\u003e4.00A\u003c\/td\u003e\n\u003ctd\u003e20W\u003c\/td\u003e\n\u003ctd\u003e75mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e5.75V - 7.75V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0903N01\u003c\/td\u003e\n\u003ctd\u003e9.0V\u003c\/td\u003e\n\u003ctd\u003e3.00A\u003c\/td\u003e\n\u003ctd\u003e27W\u003c\/td\u003e\n\u003ctd\u003e90mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e11.7V - 16.2V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A1203N01\u003c\/td\u003e\n\u003ctd\u003e12.0V\u003c\/td\u003e\n\u003ctd\u003e2.50A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e120mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e14.4V - 16.8V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A1503N01\u003c\/td\u003e\n\u003ctd\u003e15.0V\u003c\/td\u003e\n\u003ctd\u003e2.00A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e150mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e18.0V - 21.0V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A1803N01\u003c\/td\u003e\n\u003ctd\u003e18.0V\u003c\/td\u003e\n\u003ctd\u003e1.67A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e180mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e21.6V - 25.2V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A2403N01\u003c\/td\u003e\n\u003ctd\u003e24.0V\u003c\/td\u003e\n\u003ctd\u003e1.33A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e240mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e28.8V - 33.6V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A4803N01\u003c\/td\u003e\n\u003ctd\u003e48.0V\u003c\/td\u003e\n\u003ctd\u003e0.63A\u003c\/td\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003ctd\u003e480mV pk-pk\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e55.0V - 60.0V\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C8, Class II, Straight Barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Models \u0026amp; Configurations\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eReceptacle\u003c\/th\u003e\n\u003cth\u003eBlade Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503F01\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C14\u003c\/td\u003e\n\u003ctd\u003eCenter positive\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503B01\u003c\/td\u003e\n\u003ctd\u003eWall Plug\u003c\/td\u003e\n\u003ctd\u003eNorth American blades\u003c\/td\u003e\n\u003ctd\u003eOrder blade kit KT-1027K for other blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503C01\u003c\/td\u003e\n\u003ctd\u003eWall Plug\u003c\/td\u003e\n\u003ctd\u003eNorth American blades\u003c\/td\u003e\n\u003ctd\u003eOrder blade kit KT-1027K for other blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eME30A0503Q01\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C18\u003c\/td\u003e\n\u003ctd\u003eCenter positive\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more details, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-me30a0503n01.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eDisclaimer\u003c\/h3\u003e\n\u003cp\u003eThe specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Performance criteria are defined as following: A – Normal performance during and after the test, B – Temporary degradation, self-recoverable, C – Temporary degradation, operator intervention required, D – Permanent damage.\u003c\/p\u003e"}