Part Number: MINT1275A5614K01
Manufacturer: ADVANCED ENERGY / SL POWER / CONDOR
Country of Origin: CN
Unit of Measure: EA
ECCN: EAR99
Package Type: BLK
Datasheet: Download Datasheet
Product Features
High-performance 275W AC/DC power supply designed for medical applications
Compact 3” x 5” x 1.4” package suitable for 1U chassis installations
Universal input voltage range of 90-264 VAC with high efficiency (typical 92%)
Approved to CSA/EN/IEC/UL60601-1, 3rd Edition with 2 x MOPP isolation for medical safety compliance
Active current sharing for redundancy in multi-unit configurations
Includes 5V standby and 12V fan outputs for system monitoring and cooling
Features inhibit, power fail, and output OK signals for system integration
Convection cooled output of 180W, with up to 275W with airflow
DC OK Signal: Open collector, HIGH after regulation
AC Power Fail: LOW with warning before power loss
Fan Output: 12V @ 1A
Inhibit Control: Connect to inhibit pin to disable output
Current Share & Remote Sense: Supports parallel operation with up to 5 units
Mechanical & EMI Compliance
Dimensions: 3.0” x 5.0” x 1.4”
Mounting holes should be grounded for EMI purposes
EMI/EMC: Meets EN55011/22 Class B, FCC Part 15, EN61000 series immunity standards
Connectors
Input
Ground
DC Output
Fan Output
Signals
Molex 09-50-3031 (Pins: 08-52-0072)
PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL
Term. 1: +Vout Term. 2: -Vout
Molex 19141-0058/0063/0083
Remote Sense (+): PIN 6
Common: PIN 7, 8
Power Good: PIN 9
DC OK: PIN 10
Inhibit: PIN 5
+5V Standby: PIN 8
For more detailed specifications and application information, please refer to the datasheet. Please note, the datasheet was not processed; search the internet for the part number for additional details.
{"id":10026999841085,"title":"MINT1275A5614K01","handle":"mint1275a5614k01","description":"\u003ch3\u003eAC\/DC Power Supply - 56V 180W\u003c\/h3\u003e\n\u003cp\u003ePart Number: MINT1275A5614K01\u003cbr\u003e\nManufacturer: ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003cbr\u003e\nCountry of Origin: CN\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: BLK\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/3mint1275_longform_ds.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance 275W AC\/DC power supply designed for medical applications\u003c\/li\u003e\n\u003cli\u003eCompact 3” x 5” x 1.4” package suitable for 1U chassis installations\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 VAC with high efficiency (typical 92%)\u003c\/li\u003e\n\u003cli\u003eApproved to CSA\/EN\/IEC\/UL60601-1, 3rd Edition with 2 x MOPP isolation for medical safety compliance\u003c\/li\u003e\n\u003cli\u003eActive current sharing for redundancy in multi-unit configurations\u003c\/li\u003e\n\u003cli\u003eIncludes 5V standby and 12V fan outputs for system monitoring and cooling\u003c\/li\u003e\n\u003cli\u003eFeatures inhibit, power fail, and output OK signals for system integration\u003c\/li\u003e\n\u003cli\u003eConvection cooled output of 180W, with up to 275W with airflow\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and backed by a 3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240VAC, ±10%, 47-63Hz, 1∅, 120–370Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e115Vac: 3A, 230Vac: 1.5A, max 3.7A at 90Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e92% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e264Vac, cold start: \u0026lt;50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e275W continuous (with airflow), 180W convection cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e56V (no output adjustment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e4.68A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e560mV pk-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000Vac, Input-Ground: 1800Vac, Output-Ground: 1500Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +70°C (full load), start-up at -40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.0” W x 5.0” L x 1.4” H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e325g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/CSA\/UL\/IEC 60601-1, 3rd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAuxiliary Signals \u0026amp; Connectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandby Output: 5V @ 200mA\u003c\/li\u003e\n\u003cli\u003eDC OK Signal: Open collector, HIGH after regulation\u003c\/li\u003e\n\u003cli\u003eAC Power Fail: LOW with warning before power loss\u003c\/li\u003e\n\u003cli\u003eFan Output: 12V @ 1A\u003c\/li\u003e\n\u003cli\u003eInhibit Control: Connect to inhibit pin to disable output\u003c\/li\u003e\n\u003cli\u003eCurrent Share \u0026amp; Remote Sense: Supports parallel operation with up to 5 units\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMechanical \u0026amp; EMI Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 3.0” x 5.0” x 1.4”\u003c\/li\u003e\n\u003cli\u003eMounting holes should be grounded for EMI purposes\u003c\/li\u003e\n\u003cli\u003eEMI\/EMC: Meets EN55011\/22 Class B, FCC Part 15, EN61000 series immunity standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConnectors\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eGround\u003c\/th\u003e\n\u003cth\u003eDC Output\u003c\/th\u003e\n\u003cth\u003eFan Output\u003c\/th\u003e\n\u003cth\u003eSignals\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolex 09-50-3031 (Pins: 08-52-0072)\u003c\/td\u003e\n\u003ctd\u003ePIN 1) AC LINE\u003cbr\u003ePIN 2) EMPTY\u003cbr\u003ePIN 3) AC NEUTRAL\u003c\/td\u003e\n\u003ctd\u003eTerm. 1: +Vout\u003cbr\u003eTerm. 2: -Vout\u003c\/td\u003e\n\u003ctd\u003eMolex 19141-0058\/0063\/0083\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Sense (+): PIN 6\u003c\/li\u003e\n\u003cli\u003eCommon: PIN 7, 8\u003c\/li\u003e\n\u003cli\u003ePower Good: PIN 9\u003c\/li\u003e\n\u003cli\u003eDC OK: PIN 10\u003c\/li\u003e\n\u003cli\u003eInhibit: PIN 5\u003c\/li\u003e\n\u003cli\u003e+5V Standby: PIN 8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eFor more detailed specifications and application information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/3mint1275_longform_ds.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Please note, the datasheet was not processed; search the internet for the part number for additional details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T18:46:54+05:30","created_at":"2025-08-15T18:46:54+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["180W","56V","AC","ADVAN-SLPO","IMPORT_CSV","IMPORT_PT2","Switching","WLDM"],"price":2325834,"price_min":2325834,"price_max":2325834,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50623584928061,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MINT1275A5614K01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MINT1275A5614K01","public_title":null,"options":["Default Title"],"price":2325834,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"MINT1275A5614K01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1275A5614K01_44416018_c937b1f2.jpg?v=1755263817"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1275A5614K01_44416018_c937b1f2.jpg?v=1755263817","options":["Title"],"media":[{"alt":null,"id":45854511759677,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1275A5614K01_44416018_c937b1f2.jpg?v=1755263817"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT1275A5614K01_44416018_c937b1f2.jpg?v=1755263817","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAC\/DC Power Supply - 56V 180W\u003c\/h3\u003e\n\u003cp\u003ePart Number: MINT1275A5614K01\u003cbr\u003e\nManufacturer: ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003cbr\u003e\nCountry of Origin: CN\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: BLK\u003cbr\u003e\nDatasheet: \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/3mint1275_longform_ds.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-performance 275W AC\/DC power supply designed for medical applications\u003c\/li\u003e\n\u003cli\u003eCompact 3” x 5” x 1.4” package suitable for 1U chassis installations\u003c\/li\u003e\n\u003cli\u003eUniversal input voltage range of 90-264 VAC with high efficiency (typical 92%)\u003c\/li\u003e\n\u003cli\u003eApproved to CSA\/EN\/IEC\/UL60601-1, 3rd Edition with 2 x MOPP isolation for medical safety compliance\u003c\/li\u003e\n\u003cli\u003eActive current sharing for redundancy in multi-unit configurations\u003c\/li\u003e\n\u003cli\u003eIncludes 5V standby and 12V fan outputs for system monitoring and cooling\u003c\/li\u003e\n\u003cli\u003eFeatures inhibit, power fail, and output OK signals for system integration\u003c\/li\u003e\n\u003cli\u003eConvection cooled output of 180W, with up to 275W with airflow\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and backed by a 3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240VAC, ±10%, 47-63Hz, 1∅, 120–370Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e115Vac: 3A, 230Vac: 1.5A, max 3.7A at 90Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e92% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e264Vac, cold start: \u0026lt;50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e275W continuous (with airflow), 180W convection cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e56V (no output adjustment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e4.68A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e560mV pk-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000Vac, Input-Ground: 1800Vac, Output-Ground: 1500Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +70°C (full load), start-up at -40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.0” W x 5.0” L x 1.4” H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e325g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/CSA\/UL\/IEC 60601-1, 3rd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAuxiliary Signals \u0026amp; Connectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandby Output: 5V @ 200mA\u003c\/li\u003e\n\u003cli\u003eDC OK Signal: Open collector, HIGH after regulation\u003c\/li\u003e\n\u003cli\u003eAC Power Fail: LOW with warning before power loss\u003c\/li\u003e\n\u003cli\u003eFan Output: 12V @ 1A\u003c\/li\u003e\n\u003cli\u003eInhibit Control: Connect to inhibit pin to disable output\u003c\/li\u003e\n\u003cli\u003eCurrent Share \u0026amp; Remote Sense: Supports parallel operation with up to 5 units\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMechanical \u0026amp; EMI Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 3.0” x 5.0” x 1.4”\u003c\/li\u003e\n\u003cli\u003eMounting holes should be grounded for EMI purposes\u003c\/li\u003e\n\u003cli\u003eEMI\/EMC: Meets EN55011\/22 Class B, FCC Part 15, EN61000 series immunity standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConnectors\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eGround\u003c\/th\u003e\n\u003cth\u003eDC Output\u003c\/th\u003e\n\u003cth\u003eFan Output\u003c\/th\u003e\n\u003cth\u003eSignals\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolex 09-50-3031 (Pins: 08-52-0072)\u003c\/td\u003e\n\u003ctd\u003ePIN 1) AC LINE\u003cbr\u003ePIN 2) EMPTY\u003cbr\u003ePIN 3) AC NEUTRAL\u003c\/td\u003e\n\u003ctd\u003eTerm. 1: +Vout\u003cbr\u003eTerm. 2: -Vout\u003c\/td\u003e\n\u003ctd\u003eMolex 19141-0058\/0063\/0083\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Sense (+): PIN 6\u003c\/li\u003e\n\u003cli\u003eCommon: PIN 7, 8\u003c\/li\u003e\n\u003cli\u003ePower Good: PIN 9\u003c\/li\u003e\n\u003cli\u003eDC OK: PIN 10\u003c\/li\u003e\n\u003cli\u003eInhibit: PIN 5\u003c\/li\u003e\n\u003cli\u003e+5V Standby: PIN 8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eFor more detailed specifications and application information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-cod\/3mint1275_longform_ds.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Please note, the datasheet was not processed; search the internet for the part number for additional details.\u003c\/p\u003e\u003cbr\u003e"}