AC-DC Regulated Power Supply Module 270W - MINT2270A1976E01
Introducing the ADVANCED ENERGY / SL POWER / CONDOR AC-DC Power Supply Module, designed for reliable performance in medical and industrial applications. This 270W switching power supply features high efficiency, comprehensive safety standards, and versatile input/output options.
Remote ON/OFF configuration options available (model suffix “01” for OFF, “02” for ON)
DC-OK and AC-OK signals active for system monitoring
Designed to meet RoHS compliance and safety standards
Suitable for medical applications with UL/IEC/EN60601-1 approval
For more detailed specifications, please refer to the datasheet. Datasheet was not processed, please search the internet for the part number for more details.
{"id":10026708533565,"title":"MINT2270A1976E01","handle":"mint2270a1976e01","description":"\u003ch3\u003eAC-DC Regulated Power Supply Module 270W - MINT2270A1976E01\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e AC-DC Power Supply Module, designed for reliable performance in medical and industrial applications. This 270W switching power supply features high efficiency, comprehensive safety standards, and versatile input\/output options.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MINT2270A1976E01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-mint2270a1976e01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e270W continuous power output with dual output configuration\u003c\/li\u003e\n\u003cli\u003eUniversal AC input voltage range: 100-240VAC +\/- 10%, 47-63Hz\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 90% for reduced energy consumption\u003c\/li\u003e\n\u003cli\u003eNatural Interleaving Technology for Power Factor Correction (PFC)\u003c\/li\u003e\n\u003cli\u003eLLC Technology for DC conversion enhances performance and reliability\u003c\/li\u003e\n\u003cli\u003eConvection cooled design for maintenance-free operation\u003c\/li\u003e\n\u003cli\u003eRemote ON\/OFF control via PS-ON signal\u003c\/li\u003e\n\u003cli\u003eCompliance with medical safety standards: EN\/IEC\/UL 60601-1, CSA22.2 No. 60601.1\u003c\/li\u003e\n\u003cli\u003eProtection features include overvoltage, overload, short circuit, and overtemperature with auto-recovery\u003c\/li\u003e\n\u003cli\u003eIsolation: Input-Output 4000VAC, Input-Ground 1500VAC, Output-Ground 707VDC\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: Max 1% pk-pk measured at 20MHz bandwidth\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: 0°C to 70°C (derating applies)\u003c\/li\u003e\n\u003cli\u003eMTBF: 325,000 hours at 40°C ambient\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003e100-240VAC +\/- 10%, 47-63Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e115VAC: 3.0A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003eNot exceeding 45A at 264VAC cold start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003eComplies with EN61000-3-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e270W continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e1% pk-pk max., 20MHz BW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000VAC; Input-Ground: 1500VAC; Output-Ground: 707VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (refer to derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003e3.35”W x 7.17”L x 1.17”H; 550 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e325,000 hours at 40°C ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote ON\/OFF configuration options available (model suffix “01” for OFF, “02” for ON)\u003c\/li\u003e\n\u003cli\u003eDC-OK and AC-OK signals active for system monitoring\u003c\/li\u003e\n\u003cli\u003eDesigned to meet RoHS compliance and safety standards\u003c\/li\u003e\n\u003cli\u003eSuitable for medical applications with UL\/IEC\/EN60601-1 approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-mint2270a1976e01.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T13:58:40+05:30","created_at":"2025-08-15T13:58:42+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["270W","AC","ADVAN-SLPO","IMPORT_CSV","IMPORT_PT2","Power","Switching","WLDM"],"price":1458532,"price_min":1458532,"price_max":1458532,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50622988058941,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MINT2270A1976E01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MINT2270A1976E01","public_title":null,"options":["Default Title"],"price":1458532,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"MINT2270A1976E01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT2270A1976E01_11159542_25a0a171.jpg?v=1755246522"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT2270A1976E01_11159542_25a0a171.jpg?v=1755246522","options":["Title"],"media":[{"alt":null,"id":45851260911933,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT2270A1976E01_11159542_25a0a171.jpg?v=1755246522"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MINT2270A1976E01_11159542_25a0a171.jpg?v=1755246522","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAC-DC Regulated Power Supply Module 270W - MINT2270A1976E01\u003c\/h3\u003e\n\u003cp\u003eIntroducing the \u003cstrong\u003eADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/strong\u003e AC-DC Power Supply Module, designed for reliable performance in medical and industrial applications. This 270W switching power supply features high efficiency, comprehensive safety standards, and versatile input\/output options.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MINT2270A1976E01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ADVANCED ENERGY \/ SL POWER \/ CONDOR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-mint2270a1976e01.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e270W continuous power output with dual output configuration\u003c\/li\u003e\n\u003cli\u003eUniversal AC input voltage range: 100-240VAC +\/- 10%, 47-63Hz\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 90% for reduced energy consumption\u003c\/li\u003e\n\u003cli\u003eNatural Interleaving Technology for Power Factor Correction (PFC)\u003c\/li\u003e\n\u003cli\u003eLLC Technology for DC conversion enhances performance and reliability\u003c\/li\u003e\n\u003cli\u003eConvection cooled design for maintenance-free operation\u003c\/li\u003e\n\u003cli\u003eRemote ON\/OFF control via PS-ON signal\u003c\/li\u003e\n\u003cli\u003eCompliance with medical safety standards: EN\/IEC\/UL 60601-1, CSA22.2 No. 60601.1\u003c\/li\u003e\n\u003cli\u003eProtection features include overvoltage, overload, short circuit, and overtemperature with auto-recovery\u003c\/li\u003e\n\u003cli\u003eIsolation: Input-Output 4000VAC, Input-Ground 1500VAC, Output-Ground 707VDC\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: Max 1% pk-pk measured at 20MHz bandwidth\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: 0°C to 70°C (derating applies)\u003c\/li\u003e\n\u003cli\u003eMTBF: 325,000 hours at 40°C ambient\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003e100-240VAC +\/- 10%, 47-63Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e115VAC: 3.0A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003eNot exceeding 45A at 264VAC cold start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003eComplies with EN61000-3-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e270W continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e1% pk-pk max., 20MHz BW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eInput-Output: 4000VAC; Input-Ground: 1500VAC; Output-Ground: 707VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C (refer to derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003e3.35”W x 7.17”L x 1.17”H; 550 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e325,000 hours at 40°C ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote ON\/OFF configuration options available (model suffix “01” for OFF, “02” for ON)\u003c\/li\u003e\n\u003cli\u003eDC-OK and AC-OK signals active for system monitoring\u003c\/li\u003e\n\u003cli\u003eDesigned to meet RoHS compliance and safety standards\u003c\/li\u003e\n\u003cli\u003eSuitable for medical applications with UL\/IEC\/EN60601-1 approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cod\/cod-mint2270a1976e01.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e"}