Introducing the Honeywell MLH Series Heavy Duty Pressure Transducer, a high-performance sensor designed for demanding industrial applications. With a part number of MLH016BGG01B, this sensor offers precise pressure measurement across a wide range of environments.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10026196828477,"title":"MLH016BGG01B","handle":"mlh016bgg01b","description":"\u003ch3\u003eIndustrial Pressure Sensors SST PRESS TRANSDUCER - MLH016BGG01B\u003c\/h3\u003e\n\u003cp\u003eIntroducing the Honeywell MLH Series Heavy Duty Pressure Transducer, a high-performance sensor designed for demanding industrial applications. With a part number of \u003cstrong\u003eMLH016BGG01B\u003c\/strong\u003e, this sensor offers precise pressure measurement across a wide range of environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-mr\/69122372246396honeywell-sensing-heavy-duty-pressure-transducers-mlh-series-data.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombines ASIC technology with a media-isolated, metal diaphragm design for durability and accuracy\u003c\/li\u003e\n\u003cli\u003eFully temperature compensated, calibrated, and amplified for reliable performance\u003c\/li\u003e\n\u003cli\u003eAvailable in pressure ranges from 6 bar to 550 bar (50 psi to 8,000 psi)\u003c\/li\u003e\n\u003cli\u003eOffers ±0.25% full scale accuracy (BFSL) and a Total Error Band as low as 2% over -40 °C to 125 °C (-40 °F to 257 °F)\u003c\/li\u003e\n\u003cli\u003eIndustry-standard electrical connectors and pressure ports for enhanced reliability and flexibility\u003c\/li\u003e\n\u003cli\u003eSix standard output options including ratiometric, current, and regulated voltage signals\u003c\/li\u003e\n\u003cli\u003eAll metal wetted parts suitable for various fluid applications\u003c\/li\u003e\n\u003cli\u003eNo internal elastomeric seals, eliminating O-ring compatibility issues\u003c\/li\u003e\n\u003cli\u003eAmplified outputs reduce external amplifier requirements\u003c\/li\u003e\n\u003cli\u003eInput reverse voltage protection guards against mis-wiring\u003c\/li\u003e\n\u003cli\u003eResponse time less than 2 ms for high-speed measurements\u003c\/li\u003e\n\u003cli\u003eRated IP65 or better for harsh environment protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial: Compressors, cylinder tank pressure, HVAC, hydraulics, oil and gas, refrigeration, water distribution\u003c\/li\u003e\n\u003cli\u003eTransportation: Braking systems, alternative fuels\u003c\/li\u003e\n\u003cli\u003eMedical: Anesthesia machines, blood analyzers, chemistry analyzers, gas chromatography, oxygen concentrators, ventilators\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePressure Range\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure (bar)\u003c\/th\u003e\n\u003cth\u003eOperating Pressure\u003c\/th\u003e\n\u003cth\u003eProof Pressure\u003c\/th\u003e\n\u003cth\u003eBurst Pressure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e1600\u003c\/td\u003e\n\u003ctd\u003e1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e825\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Output Options\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eOutput Signal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Output\u003c\/td\u003e\n\u003ctd\u003e0.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Span\u003c\/td\u003e\n\u003ctd\u003e4 Vdc (0.5 Vdc to 4.5 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation\u003c\/td\u003e\n\u003ctd\u003e5 Vdc (6 Vdc max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e4 mA typ., 8 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e25 Ohm max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial in contact with media\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304L Haynes 214 alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eBlack plastic – Amodel AS-4133 HS – PPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.0 g (2.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e100 g peak (11 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eMIL-STD-810C, Random Vibration Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Operating \u0026amp; Storage)\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 125 °C (-40 °F to 257 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, UL Component Recognition (File No. E258956)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eFor more detailed specifications, visit the \u003ca href=\"https:\/\/sensing.honeywell.com\/sensors\/heavy-duty-pressure-transducers\" target=\"_blank\"\u003eHoneywell Heavy Duty Pressure Transducers Portfolio\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: The datasheet was not processed. Please search the internet for the part number MLH016BGG01B for more details.\u003c\/em\u003e\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T03:12:05+05:30","created_at":"2025-08-15T03:12:06+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["HWLL","IMPORT_CSV","Industrial","Sensors","SST","Transducers","WLDM"],"price":1397829,"price_min":1397829,"price_max":1397829,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50621725933885,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MLH016BGG01B","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MLH016BGG01B","public_title":null,"options":["Default Title"],"price":1397829,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"MLH016BGG01B","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/MLH016BGG01B_11938077_96b1ac04.jpg?v=1755207727"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MLH016BGG01B_11938077_96b1ac04.jpg?v=1755207727","options":["Title"],"media":[{"alt":null,"id":45845259878717,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MLH016BGG01B_11938077_96b1ac04.jpg?v=1755207727"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MLH016BGG01B_11938077_96b1ac04.jpg?v=1755207727","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eIndustrial Pressure Sensors SST PRESS TRANSDUCER - MLH016BGG01B\u003c\/h3\u003e\n\u003cp\u003eIntroducing the Honeywell MLH Series Heavy Duty Pressure Transducer, a high-performance sensor designed for demanding industrial applications. With a part number of \u003cstrong\u003eMLH016BGG01B\u003c\/strong\u003e, this sensor offers precise pressure measurement across a wide range of environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Not specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-mr\/69122372246396honeywell-sensing-heavy-duty-pressure-transducers-mlh-series-data.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombines ASIC technology with a media-isolated, metal diaphragm design for durability and accuracy\u003c\/li\u003e\n\u003cli\u003eFully temperature compensated, calibrated, and amplified for reliable performance\u003c\/li\u003e\n\u003cli\u003eAvailable in pressure ranges from 6 bar to 550 bar (50 psi to 8,000 psi)\u003c\/li\u003e\n\u003cli\u003eOffers ±0.25% full scale accuracy (BFSL) and a Total Error Band as low as 2% over -40 °C to 125 °C (-40 °F to 257 °F)\u003c\/li\u003e\n\u003cli\u003eIndustry-standard electrical connectors and pressure ports for enhanced reliability and flexibility\u003c\/li\u003e\n\u003cli\u003eSix standard output options including ratiometric, current, and regulated voltage signals\u003c\/li\u003e\n\u003cli\u003eAll metal wetted parts suitable for various fluid applications\u003c\/li\u003e\n\u003cli\u003eNo internal elastomeric seals, eliminating O-ring compatibility issues\u003c\/li\u003e\n\u003cli\u003eAmplified outputs reduce external amplifier requirements\u003c\/li\u003e\n\u003cli\u003eInput reverse voltage protection guards against mis-wiring\u003c\/li\u003e\n\u003cli\u003eResponse time less than 2 ms for high-speed measurements\u003c\/li\u003e\n\u003cli\u003eRated IP65 or better for harsh environment protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial: Compressors, cylinder tank pressure, HVAC, hydraulics, oil and gas, refrigeration, water distribution\u003c\/li\u003e\n\u003cli\u003eTransportation: Braking systems, alternative fuels\u003c\/li\u003e\n\u003cli\u003eMedical: Anesthesia machines, blood analyzers, chemistry analyzers, gas chromatography, oxygen concentrators, ventilators\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePressure Range\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure (bar)\u003c\/th\u003e\n\u003cth\u003eOperating Pressure\u003c\/th\u003e\n\u003cth\u003eProof Pressure\u003c\/th\u003e\n\u003cth\u003eBurst Pressure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e1600\u003c\/td\u003e\n\u003ctd\u003e1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e825\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003ctd\u003e2068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Output Options\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eOutput Signal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Output\u003c\/td\u003e\n\u003ctd\u003e0.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Span\u003c\/td\u003e\n\u003ctd\u003e4 Vdc (0.5 Vdc to 4.5 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation\u003c\/td\u003e\n\u003ctd\u003e5 Vdc (6 Vdc max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e4 mA typ., 8 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e25 Ohm max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial in contact with media\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304L Haynes 214 alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eBlack plastic – Amodel AS-4133 HS – PPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.0 g (2.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e100 g peak (11 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eMIL-STD-810C, Random Vibration Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range (Operating \u0026amp; Storage)\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 125 °C (-40 °F to 257 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eRoHS, CE, UL Component Recognition (File No. E258956)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eFor more detailed specifications, visit the \u003ca href=\"https:\/\/sensing.honeywell.com\/sensors\/heavy-duty-pressure-transducers\" target=\"_blank\"\u003eHoneywell Heavy Duty Pressure Transducers Portfolio\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: The datasheet was not processed. Please search the internet for the part number MLH016BGG01B for more details.\u003c\/em\u003e\u003c\/p\u003e\u003cbr\u003e"}