Product Description: MURATA MVAD040-48 AC-DC Regulated Power Supply Module 40W
The MURATA MVAD040-48 is a high-efficiency, compact AC-DC power supply module designed for industrial, medical, and telecom applications. With a power output of 40W and a standard footprint of 2" x 4", this switching power supply offers reliable performance in a low-profile, 1U package suitable for space-constrained environments.
{"id":10021578015037,"title":"MVAD040-48","handle":"mvad040-48","description":"\u003ch3\u003eProduct Description: MURATA MVAD040-48 AC-DC Regulated Power Supply Module 40W\u003c\/h3\u003e\n\u003cp\u003eThe MURATA MVAD040-48 is a high-efficiency, compact AC-DC power supply module designed for industrial, medical, and telecom applications. With a power output of 40W and a standard footprint of 2\" x 4\", this switching power supply offers reliable performance in a low-profile, 1U package suitable for space-constrained environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e MURATA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVAD040-48\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mur\/mur-mvad040-48.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh efficiency up to 89%, reducing energy consumption and operational costs\u003c\/li\u003e\n\u003cli\u003eUniversal AC input (90V to 264V AC, 47-63Hz) for worldwide compatibility\u003c\/li\u003e\n\u003cli\u003eConvection-cooled operation up to 40W with a low profile of just 1U (1.3 inches height)\u003c\/li\u003e\n\u003cli\u003eCompact footprint measuring 2\" x 4\" for easy integration into space-limited systems\u003c\/li\u003e\n\u003cli\u003eCompliance with ITE (2nd Ed.) and Medical (3rd Ed.) MOPP safety standards\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and UL Class I \u0026amp; II approved for safety and environmental standards\u003c\/li\u003e\n\u003cli\u003eLow no-load power consumption (\u0026lt;0.3W)\u003c\/li\u003e\n\u003cli\u003eDesigned to operate at altitudes up to 5000 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Operating Range\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003ctd\u003e90 Vac\u003c\/td\u003e\n\u003ctd\u003e120\/230 Vac\u003c\/td\u003e\n\u003ctd\u003e264 Vac\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e47 Hz\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e63 Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-on Input Voltage\u003c\/td\u003e\n\u003ctd\u003eFull load\u003c\/td\u003e\n\u003ctd\u003e50 Vac\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e70 Vac\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage (V1)\u003c\/td\u003e\n\u003ctd\u003eModels: 48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOutput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eMain Output Voltage (V1)\u003c\/th\u003e\n\u003cth\u003eLoad Current\u003c\/th\u003e\n\u003cth\u003ePeak Load\u003c\/th\u003e\n\u003cth\u003eLoad Capacitance\u003c\/th\u003e\n\u003cth\u003eLine, Load, Cross Regulation\u003c\/th\u003e\n\u003cth\u003eTypical Efficiency @230Vac Full Load\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMVAD040-48\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003ctd\u003e0 to 0.84A\u003c\/td\u003e\n\u003ctd\u003e1.25A\u003c\/td\u003e\n\u003ctd\u003e220μF\u003c\/td\u003e\n\u003ctd\u003e± 2%\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Characteristics\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C\u003c\/td\u003e\n\u003ctd\u003e85°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003eSee thermal derating curves\u003c\/td\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e70°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eClass I ITE deployment\u003c\/td\u003e\n\u003ctd\u003e-200 m\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003eTelcordia SR-332 M1C3 at 25°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000\u003c\/td\u003e\n\u003ctd\u003eHours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eAll models\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 lbs (123g)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProtection \u0026amp; Isolation\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e60% load\u003c\/td\u003e\n\u003ctd\u003e110%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e160% V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Primary to Earth Ground)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e240Vac, 60Hz, 25°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e300 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC60950-1:2005 (2nd Ed.) and UL60950-1 2nd Ed.\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 60950-1-07\u003c\/li\u003e\n\u003cli\u003eEN60950-1:2006 + A11:2009 + A1:2010 + A12:2011\u003c\/li\u003e\n\u003cli\u003eIEC60601-1:2005 + CORR.1(2006) + CORR.2(2007)\u003c\/li\u003e\n\u003cli\u003eANSI\/AAMI ES60601-1 (2005+C1:09 + A2:10)\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 60601-1(2008)\u003c\/li\u003e\n\u003cli\u003eMOPP CE Marking per LVD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more details, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mur\/mur-mvad040-48.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e. Discontinuance notice: \u003ca href=\"https:\/\/www.murata-ps.com\/en\/products\/discontinued-and-not-recommended.html\" target=\"_blank\"\u003eLast time buy by 2\/28\/2019\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed. Please search the internet for the part number for more details.\u003c\/em\u003e\u003c\/p\u003e","published_at":"2025-08-12T19:50:06+05:30","created_at":"2025-08-12T19:50:06+05:30","vendor":"Waldom Electonics","type":"AC-DC Power Supply","tags":["40W","AC","IMPORT_CSV","MURAT","Power","Switching","WLDM"],"price":355347,"price_min":355347,"price_max":355347,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50612748747069,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MVAD040-48","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"MVAD040-48","public_title":null,"options":["Default Title"],"price":355347,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"MVAD040-48","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/MVAD040-48_55552213_d855a383.jpg?v=1755008409"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MVAD040-48_55552213_d855a383.jpg?v=1755008409","options":["Title"],"media":[{"alt":null,"id":45804356862269,"position":1,"preview_image":{"aspect_ratio":1.08,"height":200,"width":216,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MVAD040-48_55552213_d855a383.jpg?v=1755008409"},"aspect_ratio":1.08,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/MVAD040-48_55552213_d855a383.jpg?v=1755008409","width":216}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eProduct Description: MURATA MVAD040-48 AC-DC Regulated Power Supply Module 40W\u003c\/h3\u003e\n\u003cp\u003eThe MURATA MVAD040-48 is a high-efficiency, compact AC-DC power supply module designed for industrial, medical, and telecom applications. With a power output of 40W and a standard footprint of 2\" x 4\", this switching power supply offers reliable performance in a low-profile, 1U package suitable for space-constrained environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e MURATA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVAD040-48\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mur\/mur-mvad040-48.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh efficiency up to 89%, reducing energy consumption and operational costs\u003c\/li\u003e\n\u003cli\u003eUniversal AC input (90V to 264V AC, 47-63Hz) for worldwide compatibility\u003c\/li\u003e\n\u003cli\u003eConvection-cooled operation up to 40W with a low profile of just 1U (1.3 inches height)\u003c\/li\u003e\n\u003cli\u003eCompact footprint measuring 2\" x 4\" for easy integration into space-limited systems\u003c\/li\u003e\n\u003cli\u003eCompliance with ITE (2nd Ed.) and Medical (3rd Ed.) MOPP safety standards\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and UL Class I \u0026amp; II approved for safety and environmental standards\u003c\/li\u003e\n\u003cli\u003eLow no-load power consumption (\u0026lt;0.3W)\u003c\/li\u003e\n\u003cli\u003eDesigned to operate at altitudes up to 5000 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Operating Range\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003ctd\u003e90 Vac\u003c\/td\u003e\n\u003ctd\u003e120\/230 Vac\u003c\/td\u003e\n\u003ctd\u003e264 Vac\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e47 Hz\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e63 Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-on Input Voltage\u003c\/td\u003e\n\u003ctd\u003eFull load\u003c\/td\u003e\n\u003ctd\u003e50 Vac\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e70 Vac\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage (V1)\u003c\/td\u003e\n\u003ctd\u003eModels: 48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOutput Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003cth\u003eMain Output Voltage (V1)\u003c\/th\u003e\n\u003cth\u003eLoad Current\u003c\/th\u003e\n\u003cth\u003ePeak Load\u003c\/th\u003e\n\u003cth\u003eLoad Capacitance\u003c\/th\u003e\n\u003cth\u003eLine, Load, Cross Regulation\u003c\/th\u003e\n\u003cth\u003eTypical Efficiency @230Vac Full Load\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMVAD040-48\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003ctd\u003e0 to 0.84A\u003c\/td\u003e\n\u003ctd\u003e1.25A\u003c\/td\u003e\n\u003ctd\u003e220μF\u003c\/td\u003e\n\u003ctd\u003e± 2%\u003c\/td\u003e\n\u003ctd\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Characteristics\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C\u003c\/td\u003e\n\u003ctd\u003e85°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003eSee thermal derating curves\u003c\/td\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e70°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eClass I ITE deployment\u003c\/td\u003e\n\u003ctd\u003e-200 m\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003eTelcordia SR-332 M1C3 at 25°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000\u003c\/td\u003e\n\u003ctd\u003eHours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eAll models\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 lbs (123g)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProtection \u0026amp; Isolation\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eConditions\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e60% load\u003c\/td\u003e\n\u003ctd\u003e110%\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e160% V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Primary to Earth Ground)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e240Vac, 60Hz, 25°C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e300 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompliance \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC60950-1:2005 (2nd Ed.) and UL60950-1 2nd Ed.\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 60950-1-07\u003c\/li\u003e\n\u003cli\u003eEN60950-1:2006 + A11:2009 + A1:2010 + A12:2011\u003c\/li\u003e\n\u003cli\u003eIEC60601-1:2005 + CORR.1(2006) + CORR.2(2007)\u003c\/li\u003e\n\u003cli\u003eANSI\/AAMI ES60601-1 (2005+C1:09 + A2:10)\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 60601-1(2008)\u003c\/li\u003e\n\u003cli\u003eMOPP CE Marking per LVD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more details, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mur\/mur-mvad040-48.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e. Discontinuance notice: \u003ca href=\"https:\/\/www.murata-ps.com\/en\/products\/discontinued-and-not-recommended.html\" target=\"_blank\"\u003eLast time buy by 2\/28\/2019\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Datasheet was not processed. Please search the internet for the part number for more details.\u003c\/em\u003e\u003c\/p\u003e"}