TE Connectivity / CORCOM PE0SXSH6A Power Entry Module
The TE Connectivity / CORCOM PE0SXSH6A is a versatile power entry module designed for reliable electrical connections in various applications. This power entry module features a compact footprint and multiple configuration options to meet diverse international standards and requirements.
Small footprint design suitable for space-constrained environments
Supports multiple mounting options including snap-in or flange mounting
Standard IEC 60321-1 C14 power inlet compatible with international standards
Dual voltage selection options for flexible power configurations
Optional DPST on/off switch for enhanced control
Multiple filter options including general purpose, medical, and high-performance EMI filtering
High current ratings up to 10A depending on configuration
RoHS compliant for environmentally responsible manufacturing
Technical Specifications
Parameter
Details
Rated Voltage
Maximum 250VAC
Operating Voltage
Selectable or fixed 115/230 VAC
Operating Frequency
50/60 Hz
Rated Current
Non-filtered: 10A; Filtered: 3, 6, or 10A
Leakage Current
Maximum 2A at 120VAC (H & L Models), 5A at 250VAC (S & Z Models)
Hipot Rating
Line to Ground: 2250 VDC; Line to Line: 1450 VDC
Fuse Holder
Supports one or two fuses (.25 x 1.25” or 5 x 20mm)
Switch
DPST, up to 10,000 operations at 51A inrush
Configuration Options
Mounting: Snap-in or flange
Voltage Selection: Single or dual voltage (115/230V)
Filter Types:
No filter
Interconnection block
Medical filter (H models)
High performance medical (L models)
High performance differential mode (Z models)
General purpose (S models)
Shield Options:
No shield
Filter shield
Complete shield
Complete can (for L & Z models)
Additional Details
Part Number Construction
Example: PS0SXSS6B
Features
Power entry, filter options, voltage selection, shield configurations, extenders
Extenders
J Series, L Series, C Series, or none
Filter Type Codes
S (General purpose), H (Medical), L (High Performance Medical), Z (High Performance)
Shield Options
0 (None), A (Filter shield), B (Complete shield), C (Complete can)
For more detailed specifications and configurations, please refer to the datasheet. The datasheet provides comprehensive information on features, dimensions, and electrical characteristics.
Note: The datasheet was not processed. Please search the internet for the part number PE0SXSH6A for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10049989837117,"title":"PE0SXSH6A","handle":"pe0sxsh6a-1","description":"\u003ch3\u003eTE Connectivity \/ CORCOM PE0SXSH6A Power Entry Module\u003c\/h3\u003e\n\u003cp\u003eThe TE Connectivity \/ CORCOM PE0SXSH6A is a versatile power entry module designed for reliable electrical connections in various applications. This power entry module features a compact footprint and multiple configuration options to meet diverse international standards and requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PE0SXSH6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TE CONNECTIVITY \/ CORCOM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e PKG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cor\/cor-pe0sxsh6a.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint design suitable for space-constrained environments\u003c\/li\u003e\n\u003cli\u003eSupports multiple mounting options including snap-in or flange mounting\u003c\/li\u003e\n\u003cli\u003eStandard IEC 60321-1 C14 power inlet compatible with international standards\u003c\/li\u003e\n\u003cli\u003eDual voltage selection options for flexible power configurations\u003c\/li\u003e\n\u003cli\u003eOptional DPST on\/off switch for enhanced control\u003c\/li\u003e\n\u003cli\u003eMultiple filter options including general purpose, medical, and high-performance EMI filtering\u003c\/li\u003e\n\u003cli\u003eHigh current ratings up to 10A depending on configuration\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally responsible manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003eMaximum 250VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003eSelectable or fixed 115\/230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003eNon-filtered: 10A; Filtered: 3, 6, or 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 2A at 120VAC (H \u0026amp; L Models), 5A at 250VAC (S \u0026amp; Z Models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHipot Rating\u003c\/td\u003e\n\u003ctd\u003eLine to Ground: 2250 VDC; Line to Line: 1450 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Holder\u003c\/td\u003e\n\u003ctd\u003eSupports one or two fuses (.25 x 1.25” or 5 x 20mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch\u003c\/td\u003e\n\u003ctd\u003eDPST, up to 10,000 operations at 51A inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConfiguration Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Snap-in or flange\u003c\/li\u003e\n\u003cli\u003eVoltage Selection: Single or dual voltage (115\/230V)\u003c\/li\u003e\n\u003cli\u003eFilter Types:\n\u003cul\u003e\n\u003cli\u003eNo filter\u003c\/li\u003e\n\u003cli\u003eInterconnection block\u003c\/li\u003e\n\u003cli\u003eMedical filter (H models)\u003c\/li\u003e\n\u003cli\u003eHigh performance medical (L models)\u003c\/li\u003e\n\u003cli\u003eHigh performance differential mode (Z models)\u003c\/li\u003e\n\u003cli\u003eGeneral purpose (S models)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eShield Options:\n\u003cul\u003e\n\u003cli\u003eNo shield\u003c\/li\u003e\n\u003cli\u003eFilter shield\u003c\/li\u003e\n\u003cli\u003eComplete shield\u003c\/li\u003e\n\u003cli\u003eComplete can (for L \u0026amp; Z models)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number Construction\u003c\/th\u003e\n\u003cth\u003eExample: PS0SXSS6B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003ePower entry, filter options, voltage selection, shield configurations, extenders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtenders\u003c\/td\u003e\n\u003ctd\u003eJ Series, L Series, C Series, or none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Type Codes\u003c\/td\u003e\n\u003ctd\u003eS (General purpose), H (Medical), L (High Performance Medical), Z (High Performance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Options\u003c\/td\u003e\n\u003ctd\u003e0 (None), A (Filter shield), B (Complete shield), C (Complete can)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications and configurations, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cor\/cor-pe0sxsh6a.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The datasheet provides comprehensive information on features, dimensions, and electrical characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The datasheet was not processed. Please search the internet for the part number PE0SXSH6A for more details.\u003c\/p\u003e","published_at":"2025-09-05T04:06:15+05:30","created_at":"2025-09-05T04:06:15+05:30","vendor":"Waldom Electonics","type":"","tags":["WLDM"],"price":362693,"price_min":362693,"price_max":362693,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50709407629629,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PE0SXSH6A","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"PE0SXSH6A","public_title":null,"options":["Default Title"],"price":362693,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"PE0SXSH6A","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/PE0SXSH6A_11171521_2eeb97eb.jpg?v=1757025375"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/PE0SXSH6A_11171521_2eeb97eb.jpg?v=1757025375","options":["Title"],"media":[{"alt":null,"id":46200480170301,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/PE0SXSH6A_11171521_2eeb97eb.jpg?v=1757025375"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/PE0SXSH6A_11171521_2eeb97eb.jpg?v=1757025375","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTE Connectivity \/ CORCOM PE0SXSH6A Power Entry Module\u003c\/h3\u003e\n\u003cp\u003eThe TE Connectivity \/ CORCOM PE0SXSH6A is a versatile power entry module designed for reliable electrical connections in various applications. This power entry module features a compact footprint and multiple configuration options to meet diverse international standards and requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PE0SXSH6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TE CONNECTIVITY \/ CORCOM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e PKG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cor\/cor-pe0sxsh6a.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmall footprint design suitable for space-constrained environments\u003c\/li\u003e\n\u003cli\u003eSupports multiple mounting options including snap-in or flange mounting\u003c\/li\u003e\n\u003cli\u003eStandard IEC 60321-1 C14 power inlet compatible with international standards\u003c\/li\u003e\n\u003cli\u003eDual voltage selection options for flexible power configurations\u003c\/li\u003e\n\u003cli\u003eOptional DPST on\/off switch for enhanced control\u003c\/li\u003e\n\u003cli\u003eMultiple filter options including general purpose, medical, and high-performance EMI filtering\u003c\/li\u003e\n\u003cli\u003eHigh current ratings up to 10A depending on configuration\u003c\/li\u003e\n\u003cli\u003eRoHS compliant for environmentally responsible manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003eMaximum 250VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003eSelectable or fixed 115\/230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003eNon-filtered: 10A; Filtered: 3, 6, or 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 2A at 120VAC (H \u0026amp; L Models), 5A at 250VAC (S \u0026amp; Z Models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHipot Rating\u003c\/td\u003e\n\u003ctd\u003eLine to Ground: 2250 VDC; Line to Line: 1450 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Holder\u003c\/td\u003e\n\u003ctd\u003eSupports one or two fuses (.25 x 1.25” or 5 x 20mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch\u003c\/td\u003e\n\u003ctd\u003eDPST, up to 10,000 operations at 51A inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConfiguration Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Snap-in or flange\u003c\/li\u003e\n\u003cli\u003eVoltage Selection: Single or dual voltage (115\/230V)\u003c\/li\u003e\n\u003cli\u003eFilter Types:\n\u003cul\u003e\n\u003cli\u003eNo filter\u003c\/li\u003e\n\u003cli\u003eInterconnection block\u003c\/li\u003e\n\u003cli\u003eMedical filter (H models)\u003c\/li\u003e\n\u003cli\u003eHigh performance medical (L models)\u003c\/li\u003e\n\u003cli\u003eHigh performance differential mode (Z models)\u003c\/li\u003e\n\u003cli\u003eGeneral purpose (S models)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eShield Options:\n\u003cul\u003e\n\u003cli\u003eNo shield\u003c\/li\u003e\n\u003cli\u003eFilter shield\u003c\/li\u003e\n\u003cli\u003eComplete shield\u003c\/li\u003e\n\u003cli\u003eComplete can (for L \u0026amp; Z models)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number Construction\u003c\/th\u003e\n\u003cth\u003eExample: PS0SXSS6B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003ePower entry, filter options, voltage selection, shield configurations, extenders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtenders\u003c\/td\u003e\n\u003ctd\u003eJ Series, L Series, C Series, or none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Type Codes\u003c\/td\u003e\n\u003ctd\u003eS (General purpose), H (Medical), L (High Performance Medical), Z (High Performance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Options\u003c\/td\u003e\n\u003ctd\u003e0 (None), A (Filter shield), B (Complete shield), C (Complete can)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications and configurations, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cor\/cor-pe0sxsh6a.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. The datasheet provides comprehensive information on features, dimensions, and electrical characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The datasheet was not processed. Please search the internet for the part number PE0SXSH6A for more details.\u003c\/p\u003e"}
Using this with SIM SIM8262E-M2 with Airtel 5g sim. Working seamlessly and getting download speed upto 450 mbps and upload speed upto 60 mbps. But with jio sim only 4g is working.