Pressure Switch PS80-K1-0359 by SENSTA PRESSURE & TEMP
Introducing the PS80 series automatic reset pressure switch, designed for reliable operation in industrial applications. Manufactured by SENSTA PRESSURE & TEMP in Mexico, this pressure switch features a normally closed configuration with a maximum operating pressure of 400 psig. It is suitable for use in HVAC&R systems, pumps, compressors, and other process control environments.
Hazard of electric shock, explosion, or arc flash. Disconnect all power before installation or servicing. Verify connections and replace covers before powering on. Failure to follow safety instructions can result in death or serious injury.
For more detailed information, please refer to the datasheet. If unavailable, search the internet for the part number PS80-K1-0359 for additional details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10023441236285,"title":"PS80-K1-0359","handle":"ps80-k1-0359","description":"\u003ch3\u003ePressure Switch PS80-K1-0359 by SENSTA PRESSURE \u0026amp; TEMP\u003c\/h3\u003e\n\u003cp\u003eIntroducing the PS80 series automatic reset pressure switch, designed for reliable operation in industrial applications. Manufactured by SENSTA PRESSURE \u0026amp; TEMP in Mexico, this pressure switch features a normally closed configuration with a maximum operating pressure of 400 psig. It is suitable for use in HVAC\u0026amp;R systems, pumps, compressors, and other process control environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PS80-K1-0359\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e SENSTA PRESSURE \u0026amp; TEMP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BAG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-sns\/sata-ps80-automatic20reset20pressure20switches-datasheet.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCustom engineered solutions for specific application needs\u003c\/li\u003e\n\u003cli\u003eHermetically sealed sensor for enhanced durability\u003c\/li\u003e\n\u003cli\u003eEnvironmentally sealed leads for reliable performance\u003c\/li\u003e\n\u003cli\u003eFlexible set point range with fixed set points\u003c\/li\u003e\n\u003cli\u003eSingle pole, single throw configuration\u003c\/li\u003e\n\u003cli\u003eNormally closed operation\u003c\/li\u003e\n\u003cli\u003eProven reliability with up to 100,000 cycles at rated current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Pressure\u003c\/td\u003e\n\u003ctd\u003e0 to 750 psig (50 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof Pressure\u003c\/td\u003e\n\u003ctd\u003eSet Point Proof Pressure \u0026lt; 100 psig: 250 psig (17 bar); 100-500 psig: 600 psig (41 bar); \u0026gt; 500 psig: 800 psig (55 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurst Pressure\u003c\/td\u003e\n\u003ctd\u003e5000 psig (345 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife at Rated Current\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Ratings\u003c\/td\u003e\n\u003ctd\u003e120\/240 Vac - 6.0 FLA, 36 LRA; 120\/277 Vac - 375 VA Pilot Duty; 24 Vac - 125 VA Pilot Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e750 Vrms Open Contacts; 1550 Vrms Terminals to Fitting (Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eWire Lead with Quick Connect; factory options available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (UL Rating)\u003c\/td\u003e\n\u003ctd\u003e-20°F to 176°F \/ (-29°C to 80°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid Temperature (UL Rating)\u003c\/td\u003e\n\u003ctd\u003e-65°F to 275°F \/ (-54°C to 135°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDimensions \u0026amp; Configurations\u003c\/h3\u003e\n\u003cp\u003eAll dimensions are in millimeters [inches]. Additional configurations are available; contact Sensata for details.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eOrder Example\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eFitting\u003c\/th\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003cth\u003ePressure Setting (Rel\/Act)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePS80-K1-0359\u003c\/td\u003e\n\u003ctd\u003eNC, Leaded\u003c\/td\u003e\n\u003ctd\u003e7\/16-20 UNF-2B\u003c\/td\u003e\n\u003ctd\u003e18” Leads\u003c\/td\u003e\n\u003ctd\u003e300 rel \/ 400 act psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Range: from 20 psi actuation \/ 5 psi release up to 750 psi actuation \/ 50 psi release\u003c\/li\u003e\n\u003cli\u003eFitting Types: F (Disk Type), blank (Welded Disk), F (Fitting with pressure connection)\u003c\/li\u003e\n\u003cli\u003eTermination Options: 18” wire leads, 48” wire leads, quick connect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL: File SA995 Guide SDFY2\u003c\/li\u003e\n\u003cli\u003eUL (Canada): File SA995 Guide SDFY8\u003c\/li\u003e\n\u003cli\u003ePED EN 12263: Module B\u0026amp;D\u003c\/li\u003e\n\u003cli\u003eENEC, EN60730: EN60730-1, EN60730-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarnings\u003c\/h3\u003e\n\u003cp\u003eHazard of electric shock, explosion, or arc flash. Disconnect all power before installation or servicing. Verify connections and replace covers before powering on. Failure to follow safety instructions can result in death or serious injury.\u003c\/p\u003e\n\u003cp\u003eFor more detailed information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-sns\/sata-ps80-automatic20reset20pressure20switches-datasheet.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. If unavailable, search the internet for the part number PS80-K1-0359 for additional details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-13T23:07:17+05:30","created_at":"2025-08-13T23:07:17+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["IMPORT_CSV","Industrial","Sensors","SENST","Switch","Transducers","WLDM"],"price":287438,"price_min":287438,"price_max":287438,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50616550818109,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PS80-K1-0359","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"PS80-K1-0359","public_title":null,"options":["Default Title"],"price":287438,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"PS80-K1-0359","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/PS80-K1-0359_50377193_6f49a816.jpg?v=1755106641"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/PS80-K1-0359_50377193_6f49a816.jpg?v=1755106641","options":["Title"],"media":[{"alt":null,"id":45823060803901,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/PS80-K1-0359_50377193_6f49a816.jpg?v=1755106641"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/PS80-K1-0359_50377193_6f49a816.jpg?v=1755106641","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003ePressure Switch PS80-K1-0359 by SENSTA PRESSURE \u0026amp; TEMP\u003c\/h3\u003e\n\u003cp\u003eIntroducing the PS80 series automatic reset pressure switch, designed for reliable operation in industrial applications. Manufactured by SENSTA PRESSURE \u0026amp; TEMP in Mexico, this pressure switch features a normally closed configuration with a maximum operating pressure of 400 psig. It is suitable for use in HVAC\u0026amp;R systems, pumps, compressors, and other process control environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PS80-K1-0359\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e SENSTA PRESSURE \u0026amp; TEMP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BAG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-sns\/sata-ps80-automatic20reset20pressure20switches-datasheet.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCustom engineered solutions for specific application needs\u003c\/li\u003e\n\u003cli\u003eHermetically sealed sensor for enhanced durability\u003c\/li\u003e\n\u003cli\u003eEnvironmentally sealed leads for reliable performance\u003c\/li\u003e\n\u003cli\u003eFlexible set point range with fixed set points\u003c\/li\u003e\n\u003cli\u003eSingle pole, single throw configuration\u003c\/li\u003e\n\u003cli\u003eNormally closed operation\u003c\/li\u003e\n\u003cli\u003eProven reliability with up to 100,000 cycles at rated current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Pressure\u003c\/td\u003e\n\u003ctd\u003e0 to 750 psig (50 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof Pressure\u003c\/td\u003e\n\u003ctd\u003eSet Point Proof Pressure \u0026lt; 100 psig: 250 psig (17 bar); 100-500 psig: 600 psig (41 bar); \u0026gt; 500 psig: 800 psig (55 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurst Pressure\u003c\/td\u003e\n\u003ctd\u003e5000 psig (345 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife at Rated Current\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Ratings\u003c\/td\u003e\n\u003ctd\u003e120\/240 Vac - 6.0 FLA, 36 LRA; 120\/277 Vac - 375 VA Pilot Duty; 24 Vac - 125 VA Pilot Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e750 Vrms Open Contacts; 1550 Vrms Terminals to Fitting (Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eWire Lead with Quick Connect; factory options available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (UL Rating)\u003c\/td\u003e\n\u003ctd\u003e-20°F to 176°F \/ (-29°C to 80°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid Temperature (UL Rating)\u003c\/td\u003e\n\u003ctd\u003e-65°F to 275°F \/ (-54°C to 135°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDimensions \u0026amp; Configurations\u003c\/h3\u003e\n\u003cp\u003eAll dimensions are in millimeters [inches]. Additional configurations are available; contact Sensata for details.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eOrder Example\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eFitting\u003c\/th\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003cth\u003ePressure Setting (Rel\/Act)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePS80-K1-0359\u003c\/td\u003e\n\u003ctd\u003eNC, Leaded\u003c\/td\u003e\n\u003ctd\u003e7\/16-20 UNF-2B\u003c\/td\u003e\n\u003ctd\u003e18” Leads\u003c\/td\u003e\n\u003ctd\u003e300 rel \/ 400 act psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Range: from 20 psi actuation \/ 5 psi release up to 750 psi actuation \/ 50 psi release\u003c\/li\u003e\n\u003cli\u003eFitting Types: F (Disk Type), blank (Welded Disk), F (Fitting with pressure connection)\u003c\/li\u003e\n\u003cli\u003eTermination Options: 18” wire leads, 48” wire leads, quick connect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL: File SA995 Guide SDFY2\u003c\/li\u003e\n\u003cli\u003eUL (Canada): File SA995 Guide SDFY8\u003c\/li\u003e\n\u003cli\u003ePED EN 12263: Module B\u0026amp;D\u003c\/li\u003e\n\u003cli\u003eENEC, EN60730: EN60730-1, EN60730-2-6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarnings\u003c\/h3\u003e\n\u003cp\u003eHazard of electric shock, explosion, or arc flash. Disconnect all power before installation or servicing. Verify connections and replace covers before powering on. Failure to follow safety instructions can result in death or serious injury.\u003c\/p\u003e\n\u003cp\u003eFor more detailed information, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/productfiles\/mf-sns\/sata-ps80-automatic20reset20pressure20switches-datasheet.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. If unavailable, search the internet for the part number PS80-K1-0359 for additional details.\u003c\/p\u003e\u003cbr\u003e"}