XP POWER RDQ100110S12 Isolated DC/DC Converters - Through Hole DC-DC
Enhance your electronic systems with the high-performance XP POWER RDQ100110S12 isolated DC/DC converter, designed for reliable power conversion in demanding applications. Manufactured in Taiwan, this through-hole package offers robust isolation and efficient power delivery suitable for various industrial and rail applications.
Product Features
Input Voltage Range: 66-160 VDC, with surge capability up to 180 VDC for 100 ms
Output Options: 5 V, 12 V, and 24 V models with high current capacity (up to 30 A)
Efficiency: Up to 92% for optimal power utilization
Isolation Voltage: 2250 VDC input to output, input to case, and output to case
Remote On/Off and Remote Sense for flexible control and regulation
Low ripple and noise: 100-240 mV pk-pk depending on model
Thermal Shutdown at case temperature >105°C for safety
MTBF: 380,000 hours at 25°C, ensuring long-term reliability
Operating Temperature Range: -40°C to +100°C (with derating)
RoHS compliant and evaluated to UL60950-1 and EN62368-1 safety standards
Technical Specifications
Parameter
Value
Input Voltage Range
66-160 VDC
Input Surge Voltage
180 VDC for 100 ms
Output Voltage Options
5 V, 12 V, 24 V
Output Current
Up to 30 A depending on model
Efficiency
Up to 92%
Isolation Voltage
2250 VDC
Ripple & Noise
100-240 mV pk-pk (see models)
Switching Frequency
200 kHz typical
Operating Temperature
-40°C to +100°C (derated)
MTBF
380,000 hours at 25°C
Package & Dimensions
Package Type: TUBE
Weight: Approximately 61.5 g
Mounting hole diameter: 3.2 mm (0.126 inches) with clearance hole
Additional Details
Remote On/Off: Referenced to -Vin, module on = open circuit, module off ≤ 0.8 VDC
Remote Sense: Compensates up to 10% of Vout nominal
External TVS recommended on input for protection
Compliance: EN50121-3-2, EN55011, EN55022, EN61000-4 series, and more
Operating humidity: Up to 95% non-condensing
Datasheet & Resources
For detailed specifications and application notes, please refer to the Datasheet.
Note: External components such as TVS diodes and input/output capacitors are recommended for optimal performance and safety. Please consult the datasheet for complete details.
Product Part Number: RDQ100110S12
Manufacturer: XP POWER
Country of Origin: TW
Unit of Measure: EA
ECCN: EAR99
Package Type: TUBE
Datasheet was not processed please search the internet for the part number for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10014384292157,"title":"RDQ100110S12","handle":"rdq100110s12","description":"\u003ch3\u003eXP POWER RDQ100110S12 Isolated DC\/DC Converters - Through Hole DC-DC\u003c\/h3\u003e\n\n\u003cp\u003eEnhance your electronic systems with the high-performance \u003cstrong\u003eXP POWER RDQ100110S12\u003c\/strong\u003e isolated DC\/DC converter, designed for reliable power conversion in demanding applications. Manufactured in Taiwan, this through-hole package offers robust isolation and efficient power delivery suitable for various industrial and rail applications.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eInput Voltage Range: 66-160 VDC, with surge capability up to 180 VDC for 100 ms\u003c\/li\u003e\n \u003cli\u003eOutput Options: 5 V, 12 V, and 24 V models with high current capacity (up to 30 A)\u003c\/li\u003e\n \u003cli\u003eEfficiency: Up to 92% for optimal power utilization\u003c\/li\u003e\n \u003cli\u003eIsolation Voltage: 2250 VDC input to output, input to case, and output to case\u003c\/li\u003e\n \u003cli\u003eRemote On\/Off and Remote Sense for flexible control and regulation\u003c\/li\u003e\n \u003cli\u003eLow ripple and noise: 100-240 mV pk-pk depending on model\u003c\/li\u003e\n \u003cli\u003eThermal Shutdown at case temperature \u0026gt;105°C for safety\u003c\/li\u003e\n \u003cli\u003eMTBF: 380,000 hours at 25°C, ensuring long-term reliability\u003c\/li\u003e\n \u003cli\u003eOperating Temperature Range: -40°C to +100°C (with derating)\u003c\/li\u003e\n \u003cli\u003eRoHS compliant and evaluated to UL60950-1 and EN62368-1 safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n \u003ctd\u003e66-160 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInput Surge Voltage\u003c\/td\u003e\n \u003ctd\u003e180 VDC for 100 ms\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Voltage Options\u003c\/td\u003e\n \u003ctd\u003e5 V, 12 V, 24 V\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Current\u003c\/td\u003e\n \u003ctd\u003eUp to 30 A depending on model\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEfficiency\u003c\/td\u003e\n \u003ctd\u003eUp to 92%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n \u003ctd\u003e2250 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n \u003ctd\u003e100-240 mV pk-pk (see models)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n \u003ctd\u003e200 kHz typical\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +100°C (derated)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMTBF\u003c\/td\u003e\n \u003ctd\u003e380,000 hours at 25°C\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePackage \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cp\u003ePackage Type: TUBE\u003c\/p\u003e\n\u003cp\u003eWeight: Approximately 61.5 g\u003c\/p\u003e\n\u003cp\u003eMounting hole diameter: 3.2 mm (0.126 inches) with clearance hole\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRemote On\/Off: Referenced to -Vin, module on = open circuit, module off ≤ 0.8 VDC\u003c\/li\u003e\n \u003cli\u003eRemote Sense: Compensates up to 10% of Vout nominal\u003c\/li\u003e\n \u003cli\u003eExternal TVS recommended on input for protection\u003c\/li\u003e\n \u003cli\u003eCompliance: EN50121-3-2, EN55011, EN55022, EN61000-4 series, and more\u003c\/li\u003e\n \u003cli\u003eOperating humidity: Up to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDatasheet \u0026amp; Resources\u003c\/h3\u003e\n\u003cp\u003eFor detailed specifications and application notes, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-rdq100110s12.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: External components such as TVS diodes and input\/output capacitors are recommended for optimal performance and safety. Please consult the datasheet for complete details.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eProduct Part Number: RDQ100110S12\u003cbr\u003e\nManufacturer: XP POWER\u003cbr\u003e\nCountry of Origin: TW\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: TUBE\u003c\/p\u003e\n\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-11T01:08:26+05:30","created_at":"2025-08-11T01:08:26+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["DC","IMPORT_CSV","Isolated","WLDM","XP"],"price":2622558,"price_min":2622558,"price_max":2622558,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50581653094717,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"RDQ100110S12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"RDQ100110S12","public_title":null,"options":["Default Title"],"price":2622558,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"RDQ100110S12","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/RDQ100110S12_55939637_ee9eafbe.jpg?v=1754854710"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/RDQ100110S12_55939637_ee9eafbe.jpg?v=1754854710","options":["Title"],"media":[{"alt":null,"id":45768133050685,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/RDQ100110S12_55939637_ee9eafbe.jpg?v=1754854710"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/RDQ100110S12_55939637_ee9eafbe.jpg?v=1754854710","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eXP POWER RDQ100110S12 Isolated DC\/DC Converters - Through Hole DC-DC\u003c\/h3\u003e\n\n\u003cp\u003eEnhance your electronic systems with the high-performance \u003cstrong\u003eXP POWER RDQ100110S12\u003c\/strong\u003e isolated DC\/DC converter, designed for reliable power conversion in demanding applications. Manufactured in Taiwan, this through-hole package offers robust isolation and efficient power delivery suitable for various industrial and rail applications.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eInput Voltage Range: 66-160 VDC, with surge capability up to 180 VDC for 100 ms\u003c\/li\u003e\n \u003cli\u003eOutput Options: 5 V, 12 V, and 24 V models with high current capacity (up to 30 A)\u003c\/li\u003e\n \u003cli\u003eEfficiency: Up to 92% for optimal power utilization\u003c\/li\u003e\n \u003cli\u003eIsolation Voltage: 2250 VDC input to output, input to case, and output to case\u003c\/li\u003e\n \u003cli\u003eRemote On\/Off and Remote Sense for flexible control and regulation\u003c\/li\u003e\n \u003cli\u003eLow ripple and noise: 100-240 mV pk-pk depending on model\u003c\/li\u003e\n \u003cli\u003eThermal Shutdown at case temperature \u0026gt;105°C for safety\u003c\/li\u003e\n \u003cli\u003eMTBF: 380,000 hours at 25°C, ensuring long-term reliability\u003c\/li\u003e\n \u003cli\u003eOperating Temperature Range: -40°C to +100°C (with derating)\u003c\/li\u003e\n \u003cli\u003eRoHS compliant and evaluated to UL60950-1 and EN62368-1 safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n \u003ctd\u003e66-160 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eInput Surge Voltage\u003c\/td\u003e\n \u003ctd\u003e180 VDC for 100 ms\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Voltage Options\u003c\/td\u003e\n \u003ctd\u003e5 V, 12 V, 24 V\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Current\u003c\/td\u003e\n \u003ctd\u003eUp to 30 A depending on model\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEfficiency\u003c\/td\u003e\n \u003ctd\u003eUp to 92%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n \u003ctd\u003e2250 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n \u003ctd\u003e100-240 mV pk-pk (see models)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n \u003ctd\u003e200 kHz typical\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e-40°C to +100°C (derated)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMTBF\u003c\/td\u003e\n \u003ctd\u003e380,000 hours at 25°C\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePackage \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cp\u003ePackage Type: TUBE\u003c\/p\u003e\n\u003cp\u003eWeight: Approximately 61.5 g\u003c\/p\u003e\n\u003cp\u003eMounting hole diameter: 3.2 mm (0.126 inches) with clearance hole\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eRemote On\/Off: Referenced to -Vin, module on = open circuit, module off ≤ 0.8 VDC\u003c\/li\u003e\n \u003cli\u003eRemote Sense: Compensates up to 10% of Vout nominal\u003c\/li\u003e\n \u003cli\u003eExternal TVS recommended on input for protection\u003c\/li\u003e\n \u003cli\u003eCompliance: EN50121-3-2, EN55011, EN55022, EN61000-4 series, and more\u003c\/li\u003e\n \u003cli\u003eOperating humidity: Up to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDatasheet \u0026amp; Resources\u003c\/h3\u003e\n\u003cp\u003eFor detailed specifications and application notes, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-xpp\/xpp-rdq100110s12.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eNote: External components such as TVS diodes and input\/output capacitors are recommended for optimal performance and safety. Please consult the datasheet for complete details.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eProduct Part Number: RDQ100110S12\u003cbr\u003e\nManufacturer: XP POWER\u003cbr\u003e\nCountry of Origin: TW\u003cbr\u003e\nUnit of Measure: EA\u003cbr\u003e\nECCN: EAR99\u003cbr\u003e\nPackage Type: TUBE\u003c\/p\u003e\n\n\u003cp\u003eDatasheet was not processed please search the internet for the part number for more details.\u003c\/p\u003e"}