The Honeywell SDX005IND4 is a silicon pressure sensor designed for precise measurement of low pressures, specifically in the range of 0 in H2O to 5 in H2O. This compact, cost-effective sensor features temperature compensation, calibrated zero and span, and high impedance for low power applications, making it ideal for a variety of industrial and medical applications.
Part Number: SDX005IND4
Manufacturer: Honeywell
Country of Origin (COO): MX
Unit of Measure (UOM): EA
ECCN: EAR99
Package Type: Dual Inline Package (DIP)
For detailed technical specifications, please refer to the Datasheet.
Features
Low Cost Dual Inline Package
Temperature Compensated
Calibrated Zero and Span
Small Size
Low Noise
High Impedance for Low Power Applications
Applications
Medical Equipment
Computer Peripherals
Pneumatic Controls
HVAC
Specifications
Pressure Range
0 in H2O to 5 in H2O
Operating Pressure
0 in H2O to 5 in H2O
Proof Pressure
193 in H2O
Min. Zero Pressure Offset
-1.0 mV
Typical Zero Pressure Offset
0 mV
Max. Zero Pressure Offset
+1.0 mV
Span (Full-Scale Output)
20.0 mV (ratiometric to supply voltage)
Supply Voltage (VS)
Up to 20.0 Vdc
Maximum Pressure on Port
50 psig
Operating Temperature
0 °C to 50 °C
Storage Temperature
-55 °C to 125 °C
Humidity Limits
0 % RH to 100 % RH
Performance Characteristics
Characteristic
Min.
Typ.
Max.
Unit
Linearity and Hysteresis
–
0.2 ±
1.0 ±
% FSS
Temperature Effect on Span (0 °C to 50 °C)
–
0.4 ±
2.0 ±
% FSS
Temperature Effect on Offset (0 °C to 50 °C)
–
0.2 ±
0.6 ±
mV
Response Time
–
100
µsec
Long Term Stability (Offset and Span)
–
0.1 ±
–
% FSS
Physical Dimensions
Refer to the datasheet for detailed physical dimensions and port configuration.
Electrical Connections
Output + and Output - connections are provided for integration into your system.
Warnings
Do not use these products as safety or emergency stop devices where failure could result in personal injury.
Complete installation, operation, and maintenance instructions are provided with each product.
Misuse of documentation may lead to serious injury or death.
{"id":10026912809277,"title":"SDX005IND4","handle":"sdx005ind4","description":"\u003ch3\u003eHoneywell SDX005IND4 Pressure Sensor\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell SDX005IND4 is a silicon pressure sensor designed for precise measurement of low pressures, specifically in the range of 0 in H\u003csub\u003e2\u003c\/sub\u003eO to 5 in H\u003csub\u003e2\u003c\/sub\u003eO. This compact, cost-effective sensor features temperature compensation, calibrated zero and span, and high impedance for low power applications, making it ideal for a variety of industrial and medical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e SDX005IND4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e MX\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Dual Inline Package (DIP)\u003c\/p\u003e\n\u003cp\u003eFor detailed technical specifications, please refer to the \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/HWSC\/HWSCS00312\/HWSCS00312-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eLow Cost Dual Inline Package\u003c\/li\u003e\n \u003cli\u003eTemperature Compensated\u003c\/li\u003e\n \u003cli\u003eCalibrated Zero and Span\u003c\/li\u003e\n \u003cli\u003eSmall Size\u003c\/li\u003e\n \u003cli\u003eLow Noise\u003c\/li\u003e\n \u003cli\u003eHigh Impedance for Low Power Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMedical Equipment\u003c\/li\u003e\n \u003cli\u003eComputer Peripherals\u003c\/li\u003e\n \u003cli\u003ePneumatic Controls\u003c\/li\u003e\n \u003cli\u003eHVAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003ePressure Range\u003c\/th\u003e\n \u003cth\u003e0 in H\u003csub\u003e2\u003c\/sub\u003eO to 5 in H\u003csub\u003e2\u003c\/sub\u003eO\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Pressure\u003c\/td\u003e\n \u003ctd\u003e0 in H\u003csub\u003e2\u003c\/sub\u003eO to 5 in H\u003csub\u003e2\u003c\/sub\u003eO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eProof Pressure\u003c\/td\u003e\n \u003ctd\u003e193 in H\u003csub\u003e2\u003c\/sub\u003eO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMin. Zero Pressure Offset\u003c\/td\u003e\n \u003ctd\u003e-1.0 mV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTypical Zero Pressure Offset\u003c\/td\u003e\n \u003ctd\u003e0 mV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMax. Zero Pressure Offset\u003c\/td\u003e\n \u003ctd\u003e+1.0 mV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSpan (Full-Scale Output)\u003c\/td\u003e\n \u003ctd\u003e20.0 mV (ratiometric to supply voltage)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSupply Voltage (VS)\u003c\/td\u003e\n \u003ctd\u003eUp to 20.0 Vdc\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMaximum Pressure on Port\u003c\/td\u003e\n \u003ctd\u003e50 psig\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e0 °C to 50 °C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n \u003ctd\u003e-55 °C to 125 °C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHumidity Limits\u003c\/td\u003e\n \u003ctd\u003e0 % RH to 100 % RH\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eCharacteristic\u003c\/th\u003e\n \u003cth\u003eMin.\u003c\/th\u003e\n \u003cth\u003eTyp.\u003c\/th\u003e\n \u003cth\u003eMax.\u003c\/th\u003e\n \u003cth\u003eUnit\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLinearity and Hysteresis\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.2 ±\u003c\/td\u003e\n \u003ctd\u003e1.0 ±\u003c\/td\u003e\n \u003ctd\u003e% FSS\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTemperature Effect on Span (0 °C to 50 °C)\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.4 ±\u003c\/td\u003e\n \u003ctd\u003e2.0 ±\u003c\/td\u003e\n \u003ctd\u003e% FSS\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTemperature Effect on Offset (0 °C to 50 °C)\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.2 ±\u003c\/td\u003e\n \u003ctd\u003e0.6 ±\u003c\/td\u003e\n \u003ctd\u003emV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eResponse Time\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e100\u003c\/td\u003e\n \u003ctd\u003eµsec\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLong Term Stability (Offset and Span)\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.1 ±\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e% FSS\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cp\u003eRefer to the datasheet for detailed physical dimensions and port configuration.\u003c\/p\u003e\n\u003ch3\u003eElectrical Connections\u003c\/h3\u003e\n\u003cp\u003eOutput + and Output - connections are provided for integration into your system.\u003c\/p\u003e\n\u003ch3\u003eWarnings\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDo not use these products as safety or emergency stop devices where failure could result in personal injury.\u003c\/li\u003e\n \u003cli\u003eComplete installation, operation, and maintenance instructions are provided with each product.\u003c\/li\u003e\n \u003cli\u003eMisuse of documentation may lead to serious injury or death.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more details, please visit the \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/HWSC\/HWSCS00312\/HWSCS00312-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T17:54:31+05:30","created_at":"2025-08-15T17:54:33+05:30","vendor":"Waldom Electonics","type":"","tags":["HWLL","IMPORT_CSV","IMPORT_PT2","JZ","WLDM"],"price":2602878,"price_min":2602878,"price_max":2602878,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50623359418685,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"SDX005IND4","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SDX005IND4","public_title":null,"options":["Default Title"],"price":2602878,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"SDX005IND4","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/11941543.jpg?v=1755260673"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11941543.jpg?v=1755260673","options":["Title"],"media":[{"alt":null,"id":45853689708861,"position":1,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11941543.jpg?v=1755260673"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/11941543.jpg?v=1755260673","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eHoneywell SDX005IND4 Pressure Sensor\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell SDX005IND4 is a silicon pressure sensor designed for precise measurement of low pressures, specifically in the range of 0 in H\u003csub\u003e2\u003c\/sub\u003eO to 5 in H\u003csub\u003e2\u003c\/sub\u003eO. This compact, cost-effective sensor features temperature compensation, calibrated zero and span, and high impedance for low power applications, making it ideal for a variety of industrial and medical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e SDX005IND4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin (COO):\u003c\/strong\u003e MX\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnit of Measure (UOM):\u003c\/strong\u003e EA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Dual Inline Package (DIP)\u003c\/p\u003e\n\u003cp\u003eFor detailed technical specifications, please refer to the \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/HWSC\/HWSCS00312\/HWSCS00312-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eLow Cost Dual Inline Package\u003c\/li\u003e\n \u003cli\u003eTemperature Compensated\u003c\/li\u003e\n \u003cli\u003eCalibrated Zero and Span\u003c\/li\u003e\n \u003cli\u003eSmall Size\u003c\/li\u003e\n \u003cli\u003eLow Noise\u003c\/li\u003e\n \u003cli\u003eHigh Impedance for Low Power Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMedical Equipment\u003c\/li\u003e\n \u003cli\u003eComputer Peripherals\u003c\/li\u003e\n \u003cli\u003ePneumatic Controls\u003c\/li\u003e\n \u003cli\u003eHVAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003ePressure Range\u003c\/th\u003e\n \u003cth\u003e0 in H\u003csub\u003e2\u003c\/sub\u003eO to 5 in H\u003csub\u003e2\u003c\/sub\u003eO\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Pressure\u003c\/td\u003e\n \u003ctd\u003e0 in H\u003csub\u003e2\u003c\/sub\u003eO to 5 in H\u003csub\u003e2\u003c\/sub\u003eO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eProof Pressure\u003c\/td\u003e\n \u003ctd\u003e193 in H\u003csub\u003e2\u003c\/sub\u003eO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMin. Zero Pressure Offset\u003c\/td\u003e\n \u003ctd\u003e-1.0 mV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTypical Zero Pressure Offset\u003c\/td\u003e\n \u003ctd\u003e0 mV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMax. Zero Pressure Offset\u003c\/td\u003e\n \u003ctd\u003e+1.0 mV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSpan (Full-Scale Output)\u003c\/td\u003e\n \u003ctd\u003e20.0 mV (ratiometric to supply voltage)\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSupply Voltage (VS)\u003c\/td\u003e\n \u003ctd\u003eUp to 20.0 Vdc\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMaximum Pressure on Port\u003c\/td\u003e\n \u003ctd\u003e50 psig\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n \u003ctd\u003e0 °C to 50 °C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n \u003ctd\u003e-55 °C to 125 °C\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHumidity Limits\u003c\/td\u003e\n \u003ctd\u003e0 % RH to 100 % RH\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eCharacteristic\u003c\/th\u003e\n \u003cth\u003eMin.\u003c\/th\u003e\n \u003cth\u003eTyp.\u003c\/th\u003e\n \u003cth\u003eMax.\u003c\/th\u003e\n \u003cth\u003eUnit\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLinearity and Hysteresis\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.2 ±\u003c\/td\u003e\n \u003ctd\u003e1.0 ±\u003c\/td\u003e\n \u003ctd\u003e% FSS\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTemperature Effect on Span (0 °C to 50 °C)\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.4 ±\u003c\/td\u003e\n \u003ctd\u003e2.0 ±\u003c\/td\u003e\n \u003ctd\u003e% FSS\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTemperature Effect on Offset (0 °C to 50 °C)\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.2 ±\u003c\/td\u003e\n \u003ctd\u003e0.6 ±\u003c\/td\u003e\n \u003ctd\u003emV\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eResponse Time\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e100\u003c\/td\u003e\n \u003ctd\u003eµsec\u003c\/td\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLong Term Stability (Offset and Span)\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e0.1 ±\u003c\/td\u003e\n \u003ctd\u003e–\u003c\/td\u003e\n \u003ctd\u003e% FSS\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\n\u003cp\u003eRefer to the datasheet for detailed physical dimensions and port configuration.\u003c\/p\u003e\n\u003ch3\u003eElectrical Connections\u003c\/h3\u003e\n\u003cp\u003eOutput + and Output - connections are provided for integration into your system.\u003c\/p\u003e\n\u003ch3\u003eWarnings\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eDo not use these products as safety or emergency stop devices where failure could result in personal injury.\u003c\/li\u003e\n \u003cli\u003eComplete installation, operation, and maintenance instructions are provided with each product.\u003c\/li\u003e\n \u003cli\u003eMisuse of documentation may lead to serious injury or death.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more details, please visit the \u003ca href=\"https:\/\/4donline.ihs.com\/images\/VipMasterIC\/IC\/HWSC\/HWSCS00312\/HWSCS00312-1.pdf?hkey=82A29B72BDB3BD67C626B77C2F032848\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e.\u003c\/p\u003e\u003cbr\u003e"}