The Honeywell SSCDRRN025MDAA3 is a high-precision, board-mounted pressure sensor designed for accurate differential and gage pressure measurements. Featuring industry-leading stability and accuracy, this sensor is ideal for applications requiring reliable pressure monitoring in medical, industrial, and HVAC systems.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10028236177725,"title":"SSCDRRN025MDAA3","handle":"sscdrrn025mdaa3","description":"\u003ch3\u003eHoneywell SSCDRRN025MDAA3 Pressure Sensor\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell SSCDRRN025MDAA3 is a high-precision, board-mounted pressure sensor designed for accurate differential and gage pressure measurements. Featuring industry-leading stability and accuracy, this sensor is ideal for applications requiring reliable pressure monitoring in medical, industrial, and HVAC systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SSCDRRN025MDAA3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-sscdrrn025mdaa3.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSilicon Ceramic (SSC) piezoresistive pressure sensor with ratiometric analog output\u003c\/li\u003e\n\u003cli\u003eFully calibrated and temperature compensated over -20 °C to 85 °C [-4 °F to 185 °F]\u003c\/li\u003e\n\u003cli\u003eOperates from a single power supply of 3.3 Vdc or 5.0 Vdc\u003c\/li\u003e\n\u003cli\u003eIndustry-leading long-term stability reduces calibration needs and maximizes system performance\u003c\/li\u003e\n\u003cli\u003eHigh accuracy of ±0.25 %FSS BFSL supports precise pressure measurement\u003c\/li\u003e\n\u003cli\u003eHigh burst pressure capability above 415 inH₂O (1034 mbar) and working pressure above 135 inH₂O (336 mbar)\u003c\/li\u003e\n\u003cli\u003eModular design with various package styles and pressure port options for flexible integration\u003c\/li\u003e\n\u003cli\u003eOnboard signal conditioning simplifies PCB design and reduces costs\u003c\/li\u003e\n\u003cli\u003eWide pressure range support from ±2.5 mbar to ±40 mbar\u003c\/li\u003e\n\u003cli\u003eInsensitivity to mounting orientation and vibration enhances reliability\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient operation with power consumption below 10 mW\u003c\/li\u003e\n\u003cli\u003eSmall form factor (10 mm x 10 mm) for easy placement in compact devices\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and protected by multiple patents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage (Vsupply)\u003c\/td\u003e\n\u003ctd\u003e3.27\u003c\/td\u003e\n\u003ctd\u003e4.95\u003c\/td\u003e\n\u003ctd\u003e5.05\u003c\/td\u003e\n\u003ctd\u003eVdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e±0.25\u003c\/td\u003e\n\u003ctd\u003e%FSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003ems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Materials\u003c\/td\u003e\n\u003ctd\u003eHigh temperature polyamide, alumina ceramic, epoxy, silicone, ceramic, glass, solder, silicon, gold\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eSee datasheet for detailed material info\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% RH, non-condensing; 100% condensing or direct liquid media on Port 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eMIL-STD-202F, Method 214, Condition F (20.7 g random)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003eMIL-STD-202F, Method 213B, Condition F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife\u003c\/td\u003e\n\u003ctd\u003e1 million cycles to working pressure minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolder Reflow\u003c\/td\u003e\n\u003ctd\u003eJ-STD-020D.1, Moisture Sensitivity Level 1 (unlimited floor life when stored as specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use with noncorrosive, non-ionic fluids\u003c\/li\u003e\n\u003cli\u003eSupports applications in medical, HVAC, industrial control, and more\u003c\/li\u003e\n\u003cli\u003eIndustry-leading total error band ensures measurement accuracy over temperature range\u003c\/li\u003e\n\u003cli\u003eCustom calibration options available to reduce PCB size and costs\u003c\/li\u003e\n\u003cli\u003eFor more detailed application information, refer to the datasheet or visit \u003ca href=\"https:\/\/sensing.honeywell.com\/index.cfm\/ci_id\/158532\/la_id\/1\/document\/1\/re_id\/0\" target=\"_blank\"\u003eHoneywell TruStability® Board Mount Pressure Sensors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-16T08:20:12+05:30","created_at":"2025-08-16T08:20:12+05:30","vendor":"Waldom Electonics","type":"","tags":["97V","HWLL","IMPORT_CSV","IMPORT_PT2","WLDM"],"price":481188,"price_min":481188,"price_max":481188,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50626995192125,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"SSCDRRN025MDAA3","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SSCDRRN025MDAA3","public_title":null,"options":["Default Title"],"price":481188,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"SSCDRRN025MDAA3","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/43883279.jpg?v=1755312614"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/43883279.jpg?v=1755312614","options":["Title"],"media":[{"alt":null,"id":45865506767165,"position":1,"preview_image":{"aspect_ratio":0.902,"height":600,"width":541,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/43883279.jpg?v=1755312614"},"aspect_ratio":0.902,"height":600,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/43883279.jpg?v=1755312614","width":541}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eHoneywell SSCDRRN025MDAA3 Pressure Sensor\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell SSCDRRN025MDAA3 is a high-precision, board-mounted pressure sensor designed for accurate differential and gage pressure measurements. Featuring industry-leading stability and accuracy, this sensor is ideal for applications requiring reliable pressure monitoring in medical, industrial, and HVAC systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SSCDRRN025MDAA3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e Each (EA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-mr\/mr-sscdrrn025mdaa3.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSilicon Ceramic (SSC) piezoresistive pressure sensor with ratiometric analog output\u003c\/li\u003e\n\u003cli\u003eFully calibrated and temperature compensated over -20 °C to 85 °C [-4 °F to 185 °F]\u003c\/li\u003e\n\u003cli\u003eOperates from a single power supply of 3.3 Vdc or 5.0 Vdc\u003c\/li\u003e\n\u003cli\u003eIndustry-leading long-term stability reduces calibration needs and maximizes system performance\u003c\/li\u003e\n\u003cli\u003eHigh accuracy of ±0.25 %FSS BFSL supports precise pressure measurement\u003c\/li\u003e\n\u003cli\u003eHigh burst pressure capability above 415 inH₂O (1034 mbar) and working pressure above 135 inH₂O (336 mbar)\u003c\/li\u003e\n\u003cli\u003eModular design with various package styles and pressure port options for flexible integration\u003c\/li\u003e\n\u003cli\u003eOnboard signal conditioning simplifies PCB design and reduces costs\u003c\/li\u003e\n\u003cli\u003eWide pressure range support from ±2.5 mbar to ±40 mbar\u003c\/li\u003e\n\u003cli\u003eInsensitivity to mounting orientation and vibration enhances reliability\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient operation with power consumption below 10 mW\u003c\/li\u003e\n\u003cli\u003eSmall form factor (10 mm x 10 mm) for easy placement in compact devices\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and protected by multiple patents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eMin.\u003c\/th\u003e\n\u003cth\u003eTyp.\u003c\/th\u003e\n\u003cth\u003eMax.\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage (Vsupply)\u003c\/td\u003e\n\u003ctd\u003e3.27\u003c\/td\u003e\n\u003ctd\u003e4.95\u003c\/td\u003e\n\u003ctd\u003e5.05\u003c\/td\u003e\n\u003ctd\u003eVdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e±0.25\u003c\/td\u003e\n\u003ctd\u003e%FSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003ems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Materials\u003c\/td\u003e\n\u003ctd\u003eHigh temperature polyamide, alumina ceramic, epoxy, silicone, ceramic, glass, solder, silicon, gold\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eSee datasheet for detailed material info\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% RH, non-condensing; 100% condensing or direct liquid media on Port 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eMIL-STD-202F, Method 214, Condition F (20.7 g random)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003eMIL-STD-202F, Method 213B, Condition F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife\u003c\/td\u003e\n\u003ctd\u003e1 million cycles to working pressure minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolder Reflow\u003c\/td\u003e\n\u003ctd\u003eJ-STD-020D.1, Moisture Sensitivity Level 1 (unlimited floor life when stored as specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use with noncorrosive, non-ionic fluids\u003c\/li\u003e\n\u003cli\u003eSupports applications in medical, HVAC, industrial control, and more\u003c\/li\u003e\n\u003cli\u003eIndustry-leading total error band ensures measurement accuracy over temperature range\u003c\/li\u003e\n\u003cli\u003eCustom calibration options available to reduce PCB size and costs\u003c\/li\u003e\n\u003cli\u003eFor more detailed application information, refer to the datasheet or visit \u003ca href=\"https:\/\/sensing.honeywell.com\/index.cfm\/ci_id\/158532\/la_id\/1\/document\/1\/re_id\/0\" target=\"_blank\"\u003eHoneywell TruStability® Board Mount Pressure Sensors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e"}