The Amphenol RF T6615 is a high-performance dual-channel CO2 sensor module designed for integration into existing control systems and equipment. Manufactured in the US, this compact sensor offers reliable and accurate air quality measurement suitable for various OEM applications.
Part Number: T6615 Manufacturer: Amphenol RF Country of Origin: US Unit of Measure: EA ECCN: EAR99 Package Type: BLK Datasheet:Download Datasheet
Product Features
Dual-channel Non Dispersive Infrared (NDIR) sensing technology with gold-plated optics
Sensor may be field calibrated using nitrogen gas for immediate accuracy restoration
Self-calibration occurs approximately every 24 hours or can be manually triggered
Designed for OEM integration with careful handling to prevent electrostatic discharge damage
Available models include diffusion and flow-through configurations with various ppm ranges
For more detailed specifications, please refer to the datasheet. Handling and calibration procedures should follow industry standards to ensure optimal performance.
Note: Datasheet was not processed, please search the internet for the part number T6615 for more details.
{"id":10027905286461,"title":"T6615","handle":"t6615","description":"\u003ch3\u003eAir Quality Sensors Dual Channel CO2 Module - T6615\u003c\/h3\u003e\n\u003cp\u003eThe Amphenol RF T6615 is a high-performance dual-channel CO\u003csub\u003e2\u003c\/sub\u003e sensor module designed for integration into existing control systems and equipment. Manufactured in the US, this compact sensor offers reliable and accurate air quality measurement suitable for various OEM applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e T6615\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Amphenol RF\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e US\u003cbr\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003cbr\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ah\/ah-t6615.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-channel Non Dispersive Infrared (NDIR) sensing technology with gold-plated optics\u003c\/li\u003e\n\u003cli\u003eMeasurement range options: 0-2000 ppm, 0-5000 ppm, 0-10,000 ppm, 0-50,000 ppm\u003c\/li\u003e\n\u003cli\u003eReliable design based on 15 years of engineering expertise\u003c\/li\u003e\n\u003cli\u003eFlexible platform compatible with microprocessor devices\u003c\/li\u003e\n\u003cli\u003eThree-point calibration process for enhanced stability and accuracy\u003c\/li\u003e\n\u003cli\u003eField calibration capability for maintaining measurement precision over time\u003c\/li\u003e\n\u003cli\u003eDesigned for applications where ABC Logic cannot be used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003ctd\u003eDual-channel NDIR, diffusion or flow through sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e2.25 in x 1.365 in x 0.60 in (57.15 mm x 34.67 mm x 15.24 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e75 ppm or 10% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Dependence\u003c\/th\u003e\n\u003ctd\u003e0.2% FS per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability (10 years)\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 5% of FS or \u0026lt; 10% reading annually\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure Dependence\u003c\/th\u003e\n\u003ctd\u003e0.135% of reading per mm Hg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 2 minutes for 90% step change (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarm Up Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 2 minutes (operational), 10 minutes (max accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Conditions\u003c\/th\u003e\n\u003ctd\u003e32°F to 122°F (0°C to 50°C), 0-95% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Conditions\u003c\/th\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 60°C), non condensating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eDigital UART @ 19200 Baud, Analog 0-4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e5 VDC regulated (±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePeak: 0.90 W, Average: 0.165 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface Connections\u003c\/th\u003e\n\u003ctd\u003eDesigned for 12-pin header with 0.1 in (2.54 mm) spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow Rates\u003c\/th\u003e\n\u003ctd\u003eFlow through: 50 cc\/min max; Diffusion: 80-120 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensor may be field calibrated using nitrogen gas for immediate accuracy restoration\u003c\/li\u003e\n\u003cli\u003eSelf-calibration occurs approximately every 24 hours or can be manually triggered\u003c\/li\u003e\n\u003cli\u003eDesigned for OEM integration with careful handling to prevent electrostatic discharge damage\u003c\/li\u003e\n\u003cli\u003eAvailable models include diffusion and flow-through configurations with various ppm ranges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ah\/ah-t6615.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Handling and calibration procedures should follow industry standards to ensure optimal performance.\u003c\/p\u003e\n\u003cp\u003eNote: Datasheet was not processed, please search the internet for the part number T6615 for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-16T04:31:29+05:30","created_at":"2025-08-16T04:31:29+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["Air","AMPH-RF","CO2","IMPORT_CSV","IMPORT_PT2","Sensors","Transducers","WLDM"],"price":1498862,"price_min":1498862,"price_max":1498862,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50626269184317,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"T6615","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"T6615","public_title":null,"options":["Default Title"],"price":1498862,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"T6615","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/T6615_55547508_940f1255.jpg?v=1755298893"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/T6615_55547508_940f1255.jpg?v=1755298893","options":["Title"],"media":[{"alt":null,"id":45861816893757,"position":1,"preview_image":{"aspect_ratio":1.765,"height":200,"width":353,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/T6615_55547508_940f1255.jpg?v=1755298893"},"aspect_ratio":1.765,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/T6615_55547508_940f1255.jpg?v=1755298893","width":353}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAir Quality Sensors Dual Channel CO2 Module - T6615\u003c\/h3\u003e\n\u003cp\u003eThe Amphenol RF T6615 is a high-performance dual-channel CO\u003csub\u003e2\u003c\/sub\u003e sensor module designed for integration into existing control systems and equipment. Manufactured in the US, this compact sensor offers reliable and accurate air quality measurement suitable for various OEM applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e T6615\u003cbr\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Amphenol RF\u003cbr\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e US\u003cbr\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003cbr\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e BLK\u003cbr\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ah\/ah-t6615.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-channel Non Dispersive Infrared (NDIR) sensing technology with gold-plated optics\u003c\/li\u003e\n\u003cli\u003eMeasurement range options: 0-2000 ppm, 0-5000 ppm, 0-10,000 ppm, 0-50,000 ppm\u003c\/li\u003e\n\u003cli\u003eReliable design based on 15 years of engineering expertise\u003c\/li\u003e\n\u003cli\u003eFlexible platform compatible with microprocessor devices\u003c\/li\u003e\n\u003cli\u003eThree-point calibration process for enhanced stability and accuracy\u003c\/li\u003e\n\u003cli\u003eField calibration capability for maintaining measurement precision over time\u003c\/li\u003e\n\u003cli\u003eDesigned for applications where ABC Logic cannot be used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003ctd\u003eDual-channel NDIR, diffusion or flow through sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e2.25 in x 1.365 in x 0.60 in (57.15 mm x 34.67 mm x 15.24 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e75 ppm or 10% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Dependence\u003c\/th\u003e\n\u003ctd\u003e0.2% FS per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability (10 years)\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 5% of FS or \u0026lt; 10% reading annually\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure Dependence\u003c\/th\u003e\n\u003ctd\u003e0.135% of reading per mm Hg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 2 minutes for 90% step change (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarm Up Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 2 minutes (operational), 10 minutes (max accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Conditions\u003c\/th\u003e\n\u003ctd\u003e32°F to 122°F (0°C to 50°C), 0-95% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Conditions\u003c\/th\u003e\n\u003ctd\u003e-40°F to 158°F (-40°C to 60°C), non condensating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eDigital UART @ 19200 Baud, Analog 0-4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e5 VDC regulated (±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePeak: 0.90 W, Average: 0.165 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface Connections\u003c\/th\u003e\n\u003ctd\u003eDesigned for 12-pin header with 0.1 in (2.54 mm) spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow Rates\u003c\/th\u003e\n\u003ctd\u003eFlow through: 50 cc\/min max; Diffusion: 80-120 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensor may be field calibrated using nitrogen gas for immediate accuracy restoration\u003c\/li\u003e\n\u003cli\u003eSelf-calibration occurs approximately every 24 hours or can be manually triggered\u003c\/li\u003e\n\u003cli\u003eDesigned for OEM integration with careful handling to prevent electrostatic discharge damage\u003c\/li\u003e\n\u003cli\u003eAvailable models include diffusion and flow-through configurations with various ppm ranges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-ah\/ah-t6615.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e. Handling and calibration procedures should follow industry standards to ensure optimal performance.\u003c\/p\u003e\n\u003cp\u003eNote: Datasheet was not processed, please search the internet for the part number T6615 for more details.\u003c\/p\u003e\u003cbr\u003e"}