Manufactured by TRACO ELEC. AG, the TIM 2-2412SM is a high-reliability, medical-grade isolated DC-DC converter designed for demanding applications. This compact SMD package provides robust electrical insulation and adheres to medical safety standards, making it ideal for medical equipment and other sensitive electronic systems.
Efficiency up to 82%, optimized for medical safety and reliability
Compliance with IEC 60601-1, UL 62368-1, EN 60601-1, and other safety standards
Reliability & Environmental
MTBF: approximately 6,809,000 hours
Operating temperature: -40°C to +95°C
Storage temperature: -55°C to +125°C
Vibration and mechanical shock resistant per MIL-STD-810F
RoHS and REACH compliant
Weight: 7 grams
Certifications & Standards
IEC 60601-1 3rd edition for 2xMOPP medical safety
UL 62368-1, IEC 62368-1 for multimedia and IT equipment
EMI emissions compliant with EN 55011, EN 55032, FCC Part 18 (with external filter)
EMC immunity standards including ESD, EFT, Surge, RF disturbances
For more detailed specifications, please refer to the full datasheet.
Note: The datasheet URL provided is the primary source for detailed technical information. Please search the internet for the part number TIM 2-2412SM for additional details if needed.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10022161744189,"title":"TIM 2-2412SM","handle":"tim-2-2412sm","description":"\u003ch3\u003eProduct: TIM 2-2412SM DC-DC Converter\u003c\/h3\u003e\n\u003cp\u003eManufactured by \u003cstrong\u003eTRACO ELEC. AG\u003c\/strong\u003e, the \u003cstrong\u003eTIM 2-2412SM\u003c\/strong\u003e is a high-reliability, medical-grade isolated DC-DC converter designed for demanding applications. This compact SMD package provides robust electrical insulation and adheres to medical safety standards, making it ideal for medical equipment and other sensitive electronic systems.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e TIM 2-2412SM\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TRACO ELEC. AG\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e US\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-tim-2-2412sm.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eCompact SMD-16 package for space-efficient designs\u003c\/li\u003e\n \u003cli\u003eReinforced isolation rated at 5000 VAC for medical safety compliance\u003c\/li\u003e\n \u003cli\u003eLow leakage current \u0026lt; 2 µA, suitable for patient-connected medical devices\u003c\/li\u003e\n \u003cli\u003eIEC\/EN\/ES 60601-1 3rd edition certified for 2xMOPP up to 5000 m altitude\u003c\/li\u003e\n \u003cli\u003eExtended operating temperature range from -40°C to 95°C\u003c\/li\u003e\n \u003cli\u003e5-year product warranty ensuring long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eModels\u003c\/th\u003e\n \u003cth\u003eInput Voltage Range\u003c\/th\u003e\n \u003cth\u003eOutput 1 Vnom Imax\u003c\/th\u003e\n \u003cth\u003eOutput 2 Vnom Imax\u003c\/th\u003e\n \u003cth\u003eEfficiency (%)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eTIM 2-2410SM, 2411SM, 2419SM, 2412SM, 2413SM, 2415SM, 2422SM, 2423SM\u003c\/td\u003e\n \u003ctd\u003e18 - 36 VDC (24 VDC nom.)\u003c\/td\u003e\n \u003ctd\u003e3.3 VDC \/ 5 VDC \/ 9 VDC \/ 12 VDC \/ 15 VDC \/ 24 VDC \/ +12 VDC \/ +15 VDC\u003c\/td\u003e\n \u003ctd\u003e600 mA \/ 400 mA \/ 222 mA \/ 167 mA \/ 134 mA \/ 83 mA \/ 83 mA \/ 67 mA\u003c\/td\u003e\n \u003ctd\u003e76% - 81%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTIM 2-4810SM, 4811SM, 4819SM, 4812SM, 4813SM, 4815SM, 4822SM, 4823SM\u003c\/td\u003e\n \u003ctd\u003e36 - 75 VDC (48 VDC nom.)\u003c\/td\u003e\n \u003ctd\u003e3.3 VDC \/ 5 VDC \/ 9 VDC \/ 12 VDC \/ 15 VDC \/ 24 VDC \/ +12 VDC \/ +15 VDC\u003c\/td\u003e\n \u003ctd\u003e600 mA \/ 400 mA \/ 222 mA \/ 167 mA \/ 134 mA \/ 83 mA \/ 83 mA \/ 67 mA\u003c\/td\u003e\n \u003ctd\u003e76% - 81%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eInput current at no load: 9 V models: 80 mA typ., 12 V models: 40 mA typ., 24 V models: 25 mA typ., 48 V models: 12 mA typ.\u003c\/li\u003e\n \u003cli\u003eSurge voltage withstand: 15 VDC (9 V), 25 VDC (12 V), 50 VDC (24 V), 100 VDC (48 V)\u003c\/li\u003e\n \u003cli\u003eUnder voltage lockout: 2-6 VDC depending on model\u003c\/li\u003e\n \u003cli\u003eIsolation voltage: 5000 VAC for 60 seconds\u003c\/li\u003e\n \u003cli\u003eEfficiency up to 82%, optimized for medical safety and reliability\u003c\/li\u003e\n \u003cli\u003eCompliance with IEC 60601-1, UL 62368-1, EN 60601-1, and other safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReliability \u0026amp; Environmental\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMTBF: approximately 6,809,000 hours\u003c\/li\u003e\n \u003cli\u003eOperating temperature: -40°C to +95°C\u003c\/li\u003e\n \u003cli\u003eStorage temperature: -55°C to +125°C\u003c\/li\u003e\n \u003cli\u003eVibration and mechanical shock resistant per MIL-STD-810F\u003c\/li\u003e\n \u003cli\u003eRoHS and REACH compliant\u003c\/li\u003e\n \u003cli\u003eWeight: 7 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eIEC 60601-1 3rd edition for 2xMOPP medical safety\u003c\/li\u003e\n \u003cli\u003eUL 62368-1, IEC 62368-1 for multimedia and IT equipment\u003c\/li\u003e\n \u003cli\u003eEMI emissions compliant with EN 55011, EN 55032, FCC Part 18 (with external filter)\u003c\/li\u003e\n \u003cli\u003eEMC immunity standards including ESD, EFT, Surge, RF disturbances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-tim-2-2412sm.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eNote: The datasheet URL provided is the primary source for detailed technical information. Please search the internet for the part number \u003cstrong\u003eTIM 2-2412SM\u003c\/strong\u003e for additional details if needed.\u003c\/p\u003e","published_at":"2025-08-13T04:30:33+05:30","created_at":"2025-08-13T04:30:33+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["12V","15V","2W","992W","DC","IMPORT_CSV","Isolated","Power","TIM","TRACO","WLDM"],"price":330817,"price_min":330817,"price_max":330817,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50613999763773,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"TIM 2-2412SM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"TIM 2-2412SM","public_title":null,"options":["Default Title"],"price":330817,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"TIM 2-2412SM","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/TIM_2-2412SM_54955853_ea0a4c03.jpg?v=1755039636"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/TIM_2-2412SM_54955853_ea0a4c03.jpg?v=1755039636","options":["Title"],"media":[{"alt":null,"id":45810233016637,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/TIM_2-2412SM_54955853_ea0a4c03.jpg?v=1755039636"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/TIM_2-2412SM_54955853_ea0a4c03.jpg?v=1755039636","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eProduct: TIM 2-2412SM DC-DC Converter\u003c\/h3\u003e\n\u003cp\u003eManufactured by \u003cstrong\u003eTRACO ELEC. AG\u003c\/strong\u003e, the \u003cstrong\u003eTIM 2-2412SM\u003c\/strong\u003e is a high-reliability, medical-grade isolated DC-DC converter designed for demanding applications. This compact SMD package provides robust electrical insulation and adheres to medical safety standards, making it ideal for medical equipment and other sensitive electronic systems.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e TIM 2-2412SM\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e TRACO ELEC. AG\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e US\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eUnit of Measure:\u003c\/strong\u003e EA\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eECCN:\u003c\/strong\u003e EAR99\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e TUBE\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eDatasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-tim-2-2412sm.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eCompact SMD-16 package for space-efficient designs\u003c\/li\u003e\n \u003cli\u003eReinforced isolation rated at 5000 VAC for medical safety compliance\u003c\/li\u003e\n \u003cli\u003eLow leakage current \u0026lt; 2 µA, suitable for patient-connected medical devices\u003c\/li\u003e\n \u003cli\u003eIEC\/EN\/ES 60601-1 3rd edition certified for 2xMOPP up to 5000 m altitude\u003c\/li\u003e\n \u003cli\u003eExtended operating temperature range from -40°C to 95°C\u003c\/li\u003e\n \u003cli\u003e5-year product warranty ensuring long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eModels\u003c\/th\u003e\n \u003cth\u003eInput Voltage Range\u003c\/th\u003e\n \u003cth\u003eOutput 1 Vnom Imax\u003c\/th\u003e\n \u003cth\u003eOutput 2 Vnom Imax\u003c\/th\u003e\n \u003cth\u003eEfficiency (%)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eTIM 2-2410SM, 2411SM, 2419SM, 2412SM, 2413SM, 2415SM, 2422SM, 2423SM\u003c\/td\u003e\n \u003ctd\u003e18 - 36 VDC (24 VDC nom.)\u003c\/td\u003e\n \u003ctd\u003e3.3 VDC \/ 5 VDC \/ 9 VDC \/ 12 VDC \/ 15 VDC \/ 24 VDC \/ +12 VDC \/ +15 VDC\u003c\/td\u003e\n \u003ctd\u003e600 mA \/ 400 mA \/ 222 mA \/ 167 mA \/ 134 mA \/ 83 mA \/ 83 mA \/ 67 mA\u003c\/td\u003e\n \u003ctd\u003e76% - 81%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eTIM 2-4810SM, 4811SM, 4819SM, 4812SM, 4813SM, 4815SM, 4822SM, 4823SM\u003c\/td\u003e\n \u003ctd\u003e36 - 75 VDC (48 VDC nom.)\u003c\/td\u003e\n \u003ctd\u003e3.3 VDC \/ 5 VDC \/ 9 VDC \/ 12 VDC \/ 15 VDC \/ 24 VDC \/ +12 VDC \/ +15 VDC\u003c\/td\u003e\n \u003ctd\u003e600 mA \/ 400 mA \/ 222 mA \/ 167 mA \/ 134 mA \/ 83 mA \/ 83 mA \/ 67 mA\u003c\/td\u003e\n \u003ctd\u003e76% - 81%\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eInput current at no load: 9 V models: 80 mA typ., 12 V models: 40 mA typ., 24 V models: 25 mA typ., 48 V models: 12 mA typ.\u003c\/li\u003e\n \u003cli\u003eSurge voltage withstand: 15 VDC (9 V), 25 VDC (12 V), 50 VDC (24 V), 100 VDC (48 V)\u003c\/li\u003e\n \u003cli\u003eUnder voltage lockout: 2-6 VDC depending on model\u003c\/li\u003e\n \u003cli\u003eIsolation voltage: 5000 VAC for 60 seconds\u003c\/li\u003e\n \u003cli\u003eEfficiency up to 82%, optimized for medical safety and reliability\u003c\/li\u003e\n \u003cli\u003eCompliance with IEC 60601-1, UL 62368-1, EN 60601-1, and other safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReliability \u0026amp; Environmental\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eMTBF: approximately 6,809,000 hours\u003c\/li\u003e\n \u003cli\u003eOperating temperature: -40°C to +95°C\u003c\/li\u003e\n \u003cli\u003eStorage temperature: -55°C to +125°C\u003c\/li\u003e\n \u003cli\u003eVibration and mechanical shock resistant per MIL-STD-810F\u003c\/li\u003e\n \u003cli\u003eRoHS and REACH compliant\u003c\/li\u003e\n \u003cli\u003eWeight: 7 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eIEC 60601-1 3rd edition for 2xMOPP medical safety\u003c\/li\u003e\n \u003cli\u003eUL 62368-1, IEC 62368-1 for multimedia and IT equipment\u003c\/li\u003e\n \u003cli\u003eEMI emissions compliant with EN 55011, EN 55032, FCC Part 18 (with external filter)\u003c\/li\u003e\n \u003cli\u003eEMC immunity standards including ESD, EFT, Surge, RF disturbances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more detailed specifications, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-tim-2-2412sm.pdf\" target=\"_blank\"\u003efull datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eNote: The datasheet URL provided is the primary source for detailed technical information. Please search the internet for the part number \u003cstrong\u003eTIM 2-2412SM\u003c\/strong\u003e for additional details if needed.\u003c\/p\u003e"}