Introducing the TRACO ELEC. AG TIM 2 Series DC-DC Converter, a compact and reliable power solution designed for medical and industrial applications. With a power output of 2 Watts and reinforced isolation of 5000 VAC, this converter ensures safety and performance in demanding environments.
Product Features
Compact DIP-16 package for easy integration
Reinforced isolation rated at 5000 VAC for patient safety (2xMOPP)
Low leakage current (< 2 µA) suitable for medical equipment insulation
Operating temperature range from -40°C to 95°C
Certified according to IEC/EN/ES 60601-1 3rd edition and UL 62368-1 standards
Approved for operation at altitudes up to 5000 meters
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10017780891965,"title":"TIM 2-4811","handle":"tim-2-4811","description":"\u003ch3\u003eDC-DC Converter 5V 2W - TIM 2 Series\u003c\/h3\u003e\n\u003cp\u003eIntroducing the TRACO ELEC. AG TIM 2 Series DC-DC Converter, a compact and reliable power solution designed for medical and industrial applications. With a power output of 2 Watts and reinforced isolation of 5000 VAC, this converter ensures safety and performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact DIP-16 package for easy integration\u003c\/li\u003e\n\u003cli\u003eReinforced isolation rated at 5000 VAC for patient safety (2xMOPP)\u003c\/li\u003e\n\u003cli\u003eLow leakage current (\u0026lt; 2 µA) suitable for medical equipment insulation\u003c\/li\u003e\n\u003cli\u003eOperating temperature range from -40°C to 95°C\u003c\/li\u003e\n\u003cli\u003eCertified according to IEC\/EN\/ES 60601-1 3rd edition and UL 62368-1 standards\u003c\/li\u003e\n\u003cli\u003eApproved for operation at altitudes up to 5000 meters\u003c\/li\u003e\n\u003cli\u003e5-year product warranty for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003cth\u003eOutput Voltage (Vnom)\u003c\/th\u003e\n\u003cth\u003eOutput Current (Imax)\u003c\/th\u003e\n\u003cth\u003eEfficiency (typ.)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIM 2-4811\u003c\/td\u003e\n\u003ctd\u003e36 - 75 VDC (48 VDC nom.)\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Models\u003c\/td\u003e\n\u003ctd\u003e4.5 - 12 VDC (9 VDC nom.)\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC, 9 VDC, 12 VDC, 15 VDC, 24 VDC, +12 VDC, +15 VDC\u003c\/td\u003e\n\u003ctd\u003e67 - 600 mA\u003c\/td\u003e\n\u003ctd\u003e75% - 82%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput current at no load: 12 - 80 mA depending on model\u003c\/li\u003e\n\u003cli\u003eSurge voltage withstand: up to 100 VDC (48 VDC models)\u003c\/li\u003e\n\u003cli\u003eUnder voltage lockout: 2 VDC to 29 VDC depending on model\u003c\/li\u003e\n\u003cli\u003eContinuous short circuit protection with automatic recovery\u003c\/li\u003e\n\u003cli\u003eOverload protection with foldback mode\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection: 104% - 197% of Vout nominal\u003c\/li\u003e\n\u003cli\u003eIsolation test voltage: 5000 VAC (input to output)\u003c\/li\u003e\n\u003cli\u003eInsulation resistance: ≥10,000 MΩ at 500 VDC\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and designed for medical safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Environmental Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackage Type: TUBE\u003c\/li\u003e\n\u003cli\u003eDimensions and pinout details available in datasheet\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -40°C to +95°C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -55°C to +125°C\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 7 grams\u003c\/li\u003e\n\u003cli\u003eMounting: PCB Mount, through-hole\u003c\/li\u003e\n\u003cli\u003eCooling: Natural convection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60601-1, IEC 62368-1, UL 62368-1\u003c\/li\u003e\n\u003cli\u003eEN 60601-1, ANSI\/AAMI ES 60601-1\u003c\/li\u003e\n\u003cli\u003eEMI emissions: EN 55011, EN 55032, FCC Part 18 (with external filter)\u003c\/li\u003e\n\u003cli\u003eEMC immunity: EN 61000-4 series, including ESD, EFT, surge, RF field, and conducted disturbances\u003c\/li\u003e\n\u003cli\u003ePollution Degree: PD 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDatasheet \u0026amp; Additional Resources\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical information, download the datasheet here: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-tim-2-4811.pdf\" target=\"_blank\"\u003eTIM 2-4811 Datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number: TIM 2-4811\u003c\/li\u003e\n\u003cli\u003eManufacturer: TRACO ELEC. AG\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: US\u003c\/li\u003e\n\u003cli\u003eUnit of Measure: EA\u003c\/li\u003e\n\u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e","published_at":"2025-08-11T09:11:36+05:30","created_at":"2025-08-11T09:11:36+05:30","vendor":"Waldom Electonics","type":"DC-DC Converter","tags":["2W","5V","DC","IMPORT_CSV","Isolated","TRACO","WLDM"],"price":304762,"price_min":304762,"price_max":304762,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50599681098045,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"TIM 2-4811","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"TIM 2-4811","public_title":null,"options":["Default Title"],"price":304762,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"TIM 2-4811","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/54955865.jpg?v=1754883699"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54955865.jpg?v=1754883699","options":["Title"],"media":[{"alt":null,"id":45776591520061,"position":1,"preview_image":{"aspect_ratio":1.0,"height":420,"width":420,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54955865.jpg?v=1754883699"},"aspect_ratio":1.0,"height":420,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/54955865.jpg?v=1754883699","width":420}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eDC-DC Converter 5V 2W - TIM 2 Series\u003c\/h3\u003e\n\u003cp\u003eIntroducing the TRACO ELEC. AG TIM 2 Series DC-DC Converter, a compact and reliable power solution designed for medical and industrial applications. With a power output of 2 Watts and reinforced isolation of 5000 VAC, this converter ensures safety and performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact DIP-16 package for easy integration\u003c\/li\u003e\n\u003cli\u003eReinforced isolation rated at 5000 VAC for patient safety (2xMOPP)\u003c\/li\u003e\n\u003cli\u003eLow leakage current (\u0026lt; 2 µA) suitable for medical equipment insulation\u003c\/li\u003e\n\u003cli\u003eOperating temperature range from -40°C to 95°C\u003c\/li\u003e\n\u003cli\u003eCertified according to IEC\/EN\/ES 60601-1 3rd edition and UL 62368-1 standards\u003c\/li\u003e\n\u003cli\u003eApproved for operation at altitudes up to 5000 meters\u003c\/li\u003e\n\u003cli\u003e5-year product warranty for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003cth\u003eOutput Voltage (Vnom)\u003c\/th\u003e\n\u003cth\u003eOutput Current (Imax)\u003c\/th\u003e\n\u003cth\u003eEfficiency (typ.)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTIM 2-4811\u003c\/td\u003e\n\u003ctd\u003e36 - 75 VDC (48 VDC nom.)\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003ctd\u003e78%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Models\u003c\/td\u003e\n\u003ctd\u003e4.5 - 12 VDC (9 VDC nom.)\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC, 9 VDC, 12 VDC, 15 VDC, 24 VDC, +12 VDC, +15 VDC\u003c\/td\u003e\n\u003ctd\u003e67 - 600 mA\u003c\/td\u003e\n\u003ctd\u003e75% - 82%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput current at no load: 12 - 80 mA depending on model\u003c\/li\u003e\n\u003cli\u003eSurge voltage withstand: up to 100 VDC (48 VDC models)\u003c\/li\u003e\n\u003cli\u003eUnder voltage lockout: 2 VDC to 29 VDC depending on model\u003c\/li\u003e\n\u003cli\u003eContinuous short circuit protection with automatic recovery\u003c\/li\u003e\n\u003cli\u003eOverload protection with foldback mode\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection: 104% - 197% of Vout nominal\u003c\/li\u003e\n\u003cli\u003eIsolation test voltage: 5000 VAC (input to output)\u003c\/li\u003e\n\u003cli\u003eInsulation resistance: ≥10,000 MΩ at 500 VDC\u003c\/li\u003e\n\u003cli\u003eRoHS compliant and designed for medical safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Environmental Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackage Type: TUBE\u003c\/li\u003e\n\u003cli\u003eDimensions and pinout details available in datasheet\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -40°C to +95°C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -55°C to +125°C\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 7 grams\u003c\/li\u003e\n\u003cli\u003eMounting: PCB Mount, through-hole\u003c\/li\u003e\n\u003cli\u003eCooling: Natural convection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60601-1, IEC 62368-1, UL 62368-1\u003c\/li\u003e\n\u003cli\u003eEN 60601-1, ANSI\/AAMI ES 60601-1\u003c\/li\u003e\n\u003cli\u003eEMI emissions: EN 55011, EN 55032, FCC Part 18 (with external filter)\u003c\/li\u003e\n\u003cli\u003eEMC immunity: EN 61000-4 series, including ESD, EFT, surge, RF field, and conducted disturbances\u003c\/li\u003e\n\u003cli\u003ePollution Degree: PD 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDatasheet \u0026amp; Additional Resources\u003c\/h3\u003e\n\u003cp\u003eFor detailed technical information, download the datasheet here: \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-tra\/tra-tim-2-4811.pdf\" target=\"_blank\"\u003eTIM 2-4811 Datasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number: TIM 2-4811\u003c\/li\u003e\n\u003cli\u003eManufacturer: TRACO ELEC. AG\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: US\u003c\/li\u003e\n\u003cli\u003eUnit of Measure: EA\u003c\/li\u003e\n\u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e"}