CARLO GAVAZZI Power Analyzers AV7.3 MODULE FOR WM3-96 (Part Number: AQ1019)
Enhance your electrical measurement and energy management capabilities with the CARLO GAVAZZI Power Analyzer AV7.3 Module, designed specifically for the WM3-96 series. This modular power quality analyzer offers comprehensive measurement features, communication options, and flexible configuration for professional test and measurement applications.
Product Features
Designed for 3-phase utility-grade power quality analysis, measuring main electrical variables with high accuracy (Class 0.2 for current and voltage)
Housing suitable for panel mounting with front protection ratings IP 65, NEMA 4x, and NEMA 12
Real-time clock function (without backup) for event stamping
Supports multiple communication protocols including MODBUS RTU and TCP, JBUS protocol, and iFIX SCADA compatibility
Up to 12 digital inputs for synchronization and remote control functions
Up to 16 digital outputs for pulse, alarm, and remote control signals
Configurable alarms with logical linking (OR/AND) and relay/open collector outputs
Up to 8 analogue outputs (+20mA, +10VDC, +/-5mA) for versatile signal transmission
Universal power supply options: 18-60VAC/VDC and 90-260VAC/VDC
Front display: back-lighted graph display (128x64 dots) with instantaneous power bargraph
Measures single-phase and system variables: W, var, VA, PF, VLL, VLN, A, Hz, THD, ASY VLL, ASY VLN (max, min, average)
Energy measurement: imported/exported kWh and kvarh, with support for multiple tariff management
Harmonic distortion analysis up to the 63rd harmonic with graphical and numeric indications
Data stamping of up to 10,000 events including alarms, min/max values, digital input/output status
Multiple communication ports: optical front port (ANSI C12.18), optional RS422/485, RS232, Ethernet
Measurement inputs with autoranging capability for voltage and current
Technical Specifications
Parameter
Details
Measurement Class
0.2 (current/voltage)
Display
128x64 back-lighted graph display
Protection Degree
IP 65, NEMA 4x, NEMA 12
Communication Ports
Optical front port, RS485, Ethernet, optional RS232
Inputs
Up to 12 digital inputs, 4 analogue inputs, autoranging voltage/current inputs
Outputs
Up to 16 digital outputs, 8 analogue outputs, relay and open collector outputs
Additional options including RS232+RTC, XU, SU, SY
See detailed configuration options above
For more detailed specifications and configuration options, please refer to the datasheet.
Note: Datasheet was not processed, please search the internet for the part number AQ1019 for more details.
Note: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10008701534525,"title":"AQ1019","handle":"aq1019","description":"\u003ch3\u003eCARLO GAVAZZI Power Analyzers AV7.3 MODULE FOR WM3-96 (Part Number: AQ1019)\u003c\/h3\u003e\n\u003cp\u003eEnhance your electrical measurement and energy management capabilities with the CARLO GAVAZZI Power Analyzer AV7.3 Module, designed specifically for the WM3-96 series. This modular power quality analyzer offers comprehensive measurement features, communication options, and flexible configuration for professional test and measurement applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 3-phase utility-grade power quality analysis, measuring main electrical variables with high accuracy (Class 0.2 for current and voltage)\u003c\/li\u003e\n\u003cli\u003eHousing suitable for panel mounting with front protection ratings IP 65, NEMA 4x, and NEMA 12\u003c\/li\u003e\n\u003cli\u003eReal-time clock function (without backup) for event stamping\u003c\/li\u003e\n\u003cli\u003eSupports multiple communication protocols including MODBUS RTU and TCP, JBUS protocol, and iFIX SCADA compatibility\u003c\/li\u003e\n\u003cli\u003eUp to 12 digital inputs for synchronization and remote control functions\u003c\/li\u003e\n\u003cli\u003eUp to 16 digital outputs for pulse, alarm, and remote control signals\u003c\/li\u003e\n\u003cli\u003eConfigurable alarms with logical linking (OR\/AND) and relay\/open collector outputs\u003c\/li\u003e\n\u003cli\u003eUp to 8 analogue outputs (+20mA, +10VDC, +\/-5mA) for versatile signal transmission\u003c\/li\u003e\n\u003cli\u003eUniversal power supply options: 18-60VAC\/VDC and 90-260VAC\/VDC\u003c\/li\u003e\n\u003cli\u003eFront display: back-lighted graph display (128x64 dots) with instantaneous power bargraph\u003c\/li\u003e\n\u003cli\u003eMeasures single-phase and system variables: W, var, VA, PF, VLL, VLN, A, Hz, THD, ASY VLL, ASY VLN (max, min, average)\u003c\/li\u003e\n\u003cli\u003eEnergy measurement: imported\/exported kWh and kvarh, with support for multiple tariff management\u003c\/li\u003e\n\u003cli\u003eHarmonic distortion analysis up to the 63rd harmonic with graphical and numeric indications\u003c\/li\u003e\n\u003cli\u003eData stamping of up to 10,000 events including alarms, min\/max values, digital input\/output status\u003c\/li\u003e\n\u003cli\u003eMultiple communication ports: optical front port (ANSI C12.18), optional RS422\/485, RS232, Ethernet\u003c\/li\u003e\n\u003cli\u003eMeasurement inputs with autoranging capability for voltage and current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Class\u003c\/td\u003e\n\u003ctd\u003e0.2 (current\/voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128x64 back-lighted graph display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP 65, NEMA 4x, NEMA 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eOptical front port, RS485, Ethernet, optional RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eUp to 12 digital inputs, 4 analogue inputs, autoranging voltage\/current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eUp to 16 digital outputs, 8 analogue outputs, relay and open collector outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18-60VAC\/VDC or 90-260VAC\/VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Standards\u003c\/td\u003e\n\u003ctd\u003eANSI C12.20, CA 0.5, EN62053-22 CL 0.5S, ANSI C12.1, EN62053-23 CL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Rate\u003c\/td\u003e\n\u003ctd\u003eRefresh rate of 10 times\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics Analysis\u003c\/td\u003e\n\u003ctd\u003eFFT up to 63rd harmonic, with source detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Data Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 events with timestamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase module with ANSI local port\u003c\/td\u003e\n\u003ctd\u003eAD2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase module without local port\u003c\/td\u003e\n\u003ctd\u003eAD2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply 18-60VAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAP1021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply 90-260VAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAP1020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring input (AV5: 400\/690VL-L)\u003c\/td\u003e\n\u003ctd\u003eAQ2030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring input (AV6: 120\/208VL-L)\u003c\/td\u003e\n\u003ctd\u003eAQ2031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 port (9600 bps)\u003c\/td\u003e\n\u003ctd\u003eAR1034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 port (115,200 bps)\u003c\/td\u003e\n\u003ctd\u003eAR2040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\/Internet port\u003c\/td\u003e\n\u003ctd\u003eAR1061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output (20mA DC)\u003c\/td\u003e\n\u003ctd\u003eAO2050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output (10V DC)\u003c\/td\u003e\n\u003ctd\u003eAO2051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output (+\/-5mA DC)\u003c\/td\u003e\n\u003ctd\u003eAO2052\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay output (1 or 2 channels)\u003c\/td\u003e\n\u003ctd\u003eAO1058, AO1035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen collector output (1-4 channels)\u003c\/td\u003e\n\u003ctd\u003eAO1059, AO1036, AO1037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital inputs (3 or 6 channels)\u003c\/td\u003e\n\u003ctd\u003eAQ1038, AQ1042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional options including RS232+RTC, XU, SU, SY\u003c\/td\u003e\n\u003ctd\u003eSee detailed configuration options above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications and configuration options, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cg\/cg-aq1019.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed, please search the internet for the part number AQ1019 for more details.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2025-08-08T06:19:20+05:30","created_at":"2025-08-08T06:19:20+05:30","vendor":"Waldom Electonics","type":"Test \u0026 Measurement","tags":["AV7","CARLO","IMPORT_PT2","Measurement","Power","STD_IMG","Test","WLDM"],"price":4257931,"price_min":4257931,"price_max":4257931,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50561845887293,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AQ1019","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AQ1019","public_title":null,"options":["Default Title"],"price":4257931,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"AQ1019","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_8ff1a3ae-916c-4b0f-88c2-f838a92f7b3d.jpg?v=1754614160"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_8ff1a3ae-916c-4b0f-88c2-f838a92f7b3d.jpg?v=1754614160","options":["Title"],"media":[{"alt":null,"id":45721392120125,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_8ff1a3ae-916c-4b0f-88c2-f838a92f7b3d.jpg?v=1754614160"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/fbe811dc-181f-41c1-ab5a-dc3410446d1d_8ff1a3ae-916c-4b0f-88c2-f838a92f7b3d.jpg?v=1754614160","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI Power Analyzers AV7.3 MODULE FOR WM3-96 (Part Number: AQ1019)\u003c\/h3\u003e\n\u003cp\u003eEnhance your electrical measurement and energy management capabilities with the CARLO GAVAZZI Power Analyzer AV7.3 Module, designed specifically for the WM3-96 series. This modular power quality analyzer offers comprehensive measurement features, communication options, and flexible configuration for professional test and measurement applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 3-phase utility-grade power quality analysis, measuring main electrical variables with high accuracy (Class 0.2 for current and voltage)\u003c\/li\u003e\n\u003cli\u003eHousing suitable for panel mounting with front protection ratings IP 65, NEMA 4x, and NEMA 12\u003c\/li\u003e\n\u003cli\u003eReal-time clock function (without backup) for event stamping\u003c\/li\u003e\n\u003cli\u003eSupports multiple communication protocols including MODBUS RTU and TCP, JBUS protocol, and iFIX SCADA compatibility\u003c\/li\u003e\n\u003cli\u003eUp to 12 digital inputs for synchronization and remote control functions\u003c\/li\u003e\n\u003cli\u003eUp to 16 digital outputs for pulse, alarm, and remote control signals\u003c\/li\u003e\n\u003cli\u003eConfigurable alarms with logical linking (OR\/AND) and relay\/open collector outputs\u003c\/li\u003e\n\u003cli\u003eUp to 8 analogue outputs (+20mA, +10VDC, +\/-5mA) for versatile signal transmission\u003c\/li\u003e\n\u003cli\u003eUniversal power supply options: 18-60VAC\/VDC and 90-260VAC\/VDC\u003c\/li\u003e\n\u003cli\u003eFront display: back-lighted graph display (128x64 dots) with instantaneous power bargraph\u003c\/li\u003e\n\u003cli\u003eMeasures single-phase and system variables: W, var, VA, PF, VLL, VLN, A, Hz, THD, ASY VLL, ASY VLN (max, min, average)\u003c\/li\u003e\n\u003cli\u003eEnergy measurement: imported\/exported kWh and kvarh, with support for multiple tariff management\u003c\/li\u003e\n\u003cli\u003eHarmonic distortion analysis up to the 63rd harmonic with graphical and numeric indications\u003c\/li\u003e\n\u003cli\u003eData stamping of up to 10,000 events including alarms, min\/max values, digital input\/output status\u003c\/li\u003e\n\u003cli\u003eMultiple communication ports: optical front port (ANSI C12.18), optional RS422\/485, RS232, Ethernet\u003c\/li\u003e\n\u003cli\u003eMeasurement inputs with autoranging capability for voltage and current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Class\u003c\/td\u003e\n\u003ctd\u003e0.2 (current\/voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128x64 back-lighted graph display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP 65, NEMA 4x, NEMA 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eOptical front port, RS485, Ethernet, optional RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eUp to 12 digital inputs, 4 analogue inputs, autoranging voltage\/current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eUp to 16 digital outputs, 8 analogue outputs, relay and open collector outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18-60VAC\/VDC or 90-260VAC\/VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Standards\u003c\/td\u003e\n\u003ctd\u003eANSI C12.20, CA 0.5, EN62053-22 CL 0.5S, ANSI C12.1, EN62053-23 CL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Rate\u003c\/td\u003e\n\u003ctd\u003eRefresh rate of 10 times\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics Analysis\u003c\/td\u003e\n\u003ctd\u003eFFT up to 63rd harmonic, with source detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Data Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 events with timestamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase module with ANSI local port\u003c\/td\u003e\n\u003ctd\u003eAD2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase module without local port\u003c\/td\u003e\n\u003ctd\u003eAD2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply 18-60VAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAP1021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply 90-260VAC\/DC\u003c\/td\u003e\n\u003ctd\u003eAP1020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring input (AV5: 400\/690VL-L)\u003c\/td\u003e\n\u003ctd\u003eAQ2030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring input (AV6: 120\/208VL-L)\u003c\/td\u003e\n\u003ctd\u003eAQ2031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 port (9600 bps)\u003c\/td\u003e\n\u003ctd\u003eAR1034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 port (115,200 bps)\u003c\/td\u003e\n\u003ctd\u003eAR2040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\/Internet port\u003c\/td\u003e\n\u003ctd\u003eAR1061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output (20mA DC)\u003c\/td\u003e\n\u003ctd\u003eAO2050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output (10V DC)\u003c\/td\u003e\n\u003ctd\u003eAO2051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output (+\/-5mA DC)\u003c\/td\u003e\n\u003ctd\u003eAO2052\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay output (1 or 2 channels)\u003c\/td\u003e\n\u003ctd\u003eAO1058, AO1035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen collector output (1-4 channels)\u003c\/td\u003e\n\u003ctd\u003eAO1059, AO1036, AO1037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital inputs (3 or 6 channels)\u003c\/td\u003e\n\u003ctd\u003eAQ1038, AQ1042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional options including RS232+RTC, XU, SU, SY\u003c\/td\u003e\n\u003ctd\u003eSee detailed configuration options above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more detailed specifications and configuration options, please refer to the \u003ca href=\"https:\/\/www.waldomapac.com\/upload\/parts\/datasheets\/mf-cg\/cg-aq1019.pdf\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed, please search the internet for the part number AQ1019 for more details.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote: The product image displayed is a standard reference image. Actual product appearance may vary. For the most accurate and up-to-date representation, we recommend searching the part number online.\u003c\/strong\u003e\u003c\/p\u003e"}
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.