Feel free to ask questions, share tips or report issues.
8 isolated wet-contact inputs and 8 outputs over Modbus TCP
The M140T puts 8 digital inputs and 8 digital outputs on your Ethernet network. It is an industrial, isolated data acquisition module that speaks standard Modbus TCP, so it connects straight to SCADA, OPC servers and other automation systems. An RS485 port lets it collect data from extra Modbus RTU I/O modules and meters, saving you a separate gateway.
This version uses wet-contact inputs: the input reads Logic 0 at 0ā3 V DC and Logic 1 at 10ā30 V DC.
| Specification | King Pigeon M140T |
|---|---|
| Inputs | |
| Digital Inputs | 8, optically isolated |
| Input Type | Wet contact (NPN or PNP) |
| Logic 0 / Logic 1 | 0ā3 V DC / 10ā30 V DC |
| Pulse Counting | Up to 700 kHz high-speed pulse counter |
| Outputs | |
| Digital Outputs | 8, digital or relay output |
| Pulse Output | 10 Hzā300 kHz high-speed pulse output (digital output mode) |
| Communication | |
| Ethernet | 1 Ć RJ45, 10/100M adaptive |
| Ethernet Protocols | Modbus TCP, MQTT |
| Serial | 1 Ć RS485, Modbus RTU master or slave |
| Integration | SCADA, OPC server, register mapping |
| Power and Housing | |
| Supply Voltage | 12ā36 V DC, with over-voltage and reverse-polarity protection |
| Power Output | 1 channel, 12ā36 V DC, for external devices |
| Processor | 32-bit MCU with watchdog |
| Housing | Metal, IP30 |
| Dimensions | 105 Ć 88 Ć 30 mm |
| Mounting | Wall mount or 35 mm DIN rail |
| Indicators | Status LEDs, reset button |
1 Ć M140T Ethernet Remote I/O Module
The King Pigeon M140T is a compact Modbus TCP remote I/O module with 8 isolated wet-contact inputs, 8 outputs, an RS485 expansion port and a 12ā36 V DC supply, for connecting field signals to SCADA and automation systems over Ethernet.
No reviews yet. Be the first to share your experience!
For more discussion Click Here
Fill out the form below and our team will get back to you with bulk pricing.
8 isolated wet-contact inputs and 8 outputs over Modbus TCP
The M140T puts 8 digital inputs and 8 digital outputs on your Ethernet network. It is an industrial, isolated data acquisition module that speaks standard Modbus TCP, so it connects straight to SCADA, OPC servers and other automation systems. An RS485 port lets it collect data from extra Modbus RTU I/O modules and meters, saving you a separate gateway.
This version uses wet-contact inputs: the input reads Logic 0 at 0ā3 V DC and Logic 1 at 10ā30 V DC.
| Specification | King Pigeon M140T |
|---|---|
| Inputs | |
| Digital Inputs | 8, optically isolated |
| Input Type | Wet contact (NPN or PNP) |
| Logic 0 / Logic 1 | 0ā3 V DC / 10ā30 V DC |
| Pulse Counting | Up to 700 kHz high-speed pulse counter |
| Outputs | |
| Digital Outputs | 8, digital or relay output |
| Pulse Output | 10 Hzā300 kHz high-speed pulse output (digital output mode) |
| Communication | |
| Ethernet | 1 Ć RJ45, 10/100M adaptive |
| Ethernet Protocols | Modbus TCP, MQTT |
| Serial | 1 Ć RS485, Modbus RTU master or slave |
| Integration | SCADA, OPC server, register mapping |
| Power and Housing | |
| Supply Voltage | 12ā36 V DC, with over-voltage and reverse-polarity protection |
| Power Output | 1 channel, 12ā36 V DC, for external devices |
| Processor | 32-bit MCU with watchdog |
| Housing | Metal, IP30 |
| Dimensions | 105 Ć 88 Ć 30 mm |
| Mounting | Wall mount or 35 mm DIN rail |
| Indicators | Status LEDs, reset button |
1 Ć M140T Ethernet Remote I/O Module
The King Pigeon M140T is a compact Modbus TCP remote I/O module with 8 isolated wet-contact inputs, 8 outputs, an RS485 expansion port and a 12ā36 V DC supply, for connecting field signals to SCADA and automation systems over Ethernet.