CARLO GAVAZZI ICB30L50F15PO Inductive Proximity Sensor - 15mm Sensing Distance
Enhance your industrial automation with the CARLO GAVAZZI ICB30L50F15PO inductive proximity sensor, designed for precise object detection in demanding environments. Manufactured in LT (Lithuania), this sensor offers reliable performance with a sensing distance of 15mm, extendable up to 22mm, making it ideal for applications requiring high sensing range.
Product Features
Type: Inductive proximity sensor with nickel-plated brass housing for durability
Sensing distance: 15 to 22 mm, suitable for various industrial applications
Housing: Extended length (long body) with options for flush or non-flush mounting
Output: DC 200 mA, available in NPN or PNP configurations
Output Mode: Normally open (NO) or Normally closed (NC)
Power supply: Rated operational voltage of 10 - 36 VDC
Indicators: LED for output ON, short-circuit, and overload status
Protection: Reverse polarity, short circuit, and transient protection
Connection options: Cable or M12 plug versions
Compliance: According to IEC 60947-5-2, CSA certified for Hazardous Locations
Package: Box
Part Number: ICB30L50F15PO
Manufacturer: CARLO GAVAZZI
Country of Origin: LT
UOM: EA
ECCN: EAR99
Technical Specifications
Parameter
Details
Sensing Distance
15 to 22 mm
Rated Operating Voltage (Ub)
10 - 36 VDC
Output Current
DC 200 mA
Output Type
NPN or PNP
Output Mode
Normally open or normally closed
Housing Material
Nickel-plated brass
Protection Features
Reverse polarity, short circuit, transient
Dimensions & Installation
Dimension
Size (mm)
Body Length
50 mm
Diameter
30 mm
Additional Dimensions
12 mm, 10.6 mm, 50 mm, 12 mm, 30 mm
Wiring & Mounting
Refer to the wiring diagram for proper connection. Installation guidelines include considerations for flush or non-flush mounting, with minimum spacing of 6 x sensing distance when sensors are installed opposite each other.
Ordering Options
Connection Type
Sensing Distance
Configuration
Part Number
Cable Short
15 mm
Normally open, NPN
ICB30S30F15NO
Cable Short
22 mm
Normally open, PNP
ICB30S30N22PO
Plug Short
15 mm
Normally closed, NPN
ICB30S30F15NCM1
Long Cable
15 mm
Normally open, PNP
ICB30L50F15PO
Long Cable
22 mm
Normally closed, PNP
ICB30L50N22PCM1
Additional Information
For more detailed specifications and installation instructions, please refer to the datasheet.
Note: Datasheet was not processed, please search the internet for the part number for more details.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device
Choosing a selection results in a full page refresh.
Press the space key then arrow keys to make a selection.
Shopping Cart
{"id":10026887217469,"title":"ICB30L50F15PO","handle":"icb30l50f15po","description":"\u003ch3\u003eCARLO GAVAZZI ICB30L50F15PO Inductive Proximity Sensor - 15mm Sensing Distance\u003c\/h3\u003e\n\n\u003cp\u003eEnhance your industrial automation with the CARLO GAVAZZI ICB30L50F15PO inductive proximity sensor, designed for precise object detection in demanding environments. Manufactured in LT (Lithuania), this sensor offers reliable performance with a sensing distance of 15mm, extendable up to 22mm, making it ideal for applications requiring high sensing range.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eType: Inductive proximity sensor with nickel-plated brass housing for durability\u003c\/li\u003e\n \u003cli\u003eSensing distance: 15 to 22 mm, suitable for various industrial applications\u003c\/li\u003e\n \u003cli\u003eHousing: Extended length (long body) with options for flush or non-flush mounting\u003c\/li\u003e\n \u003cli\u003eOutput: DC 200 mA, available in NPN or PNP configurations\u003c\/li\u003e\n \u003cli\u003eOutput Mode: Normally open (NO) or Normally closed (NC)\u003c\/li\u003e\n \u003cli\u003ePower supply: Rated operational voltage of 10 - 36 VDC\u003c\/li\u003e\n \u003cli\u003eIndicators: LED for output ON, short-circuit, and overload status\u003c\/li\u003e\n \u003cli\u003eProtection: Reverse polarity, short circuit, and transient protection\u003c\/li\u003e\n \u003cli\u003eConnection options: Cable or M12 plug versions\u003c\/li\u003e\n \u003cli\u003eCompliance: According to IEC 60947-5-2, CSA certified for Hazardous Locations\u003c\/li\u003e\n \u003cli\u003ePackage: Box\u003c\/li\u003e\n \u003cli\u003ePart Number: ICB30L50F15PO\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT\u003c\/li\u003e\n \u003cli\u003eUOM: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSensing Distance\u003c\/td\u003e\n \u003ctd\u003e15 to 22 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRated Operating Voltage (Ub)\u003c\/td\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Current\u003c\/td\u003e\n \u003ctd\u003eDC 200 mA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Type\u003c\/td\u003e\n \u003ctd\u003eNPN or PNP\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Mode\u003c\/td\u003e\n \u003ctd\u003eNormally open or normally closed\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHousing Material\u003c\/td\u003e\n \u003ctd\u003eNickel-plated brass\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eProtection Features\u003c\/td\u003e\n \u003ctd\u003eReverse polarity, short circuit, transient\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions \u0026amp; Installation\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eDimension\u003c\/th\u003e\n \u003cth\u003eSize (mm)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBody Length\u003c\/td\u003e\n \u003ctd\u003e50 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDiameter\u003c\/td\u003e\n \u003ctd\u003e30 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eAdditional Dimensions\u003c\/td\u003e\n \u003ctd\u003e12 mm, 10.6 mm, 50 mm, 12 mm, 30 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWiring \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eRefer to the wiring diagram for proper connection. Installation guidelines include considerations for flush or non-flush mounting, with minimum spacing of 6 x sensing distance when sensors are installed opposite each other.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Options\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eConnection Type\u003c\/th\u003e\n \u003cth\u003eSensing Distance\u003c\/th\u003e\n \u003cth\u003eConfiguration\u003c\/th\u003e\n \u003cth\u003ePart Number\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e15 mm\u003c\/td\u003e\n \u003ctd\u003eNormally open, NPN\u003c\/td\u003e\n \u003ctd\u003eICB30S30F15NO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e22 mm\u003c\/td\u003e\n \u003ctd\u003eNormally open, PNP\u003c\/td\u003e\n \u003ctd\u003eICB30S30N22PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e15 mm\u003c\/td\u003e\n \u003ctd\u003eNormally closed, NPN\u003c\/td\u003e\n \u003ctd\u003eICB30S30F15NCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLong Cable\u003c\/td\u003e\n \u003ctd\u003e15 mm\u003c\/td\u003e\n \u003ctd\u003eNormally open, PNP\u003c\/td\u003e\n \u003ctd\u003eICB30L50F15PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLong Cable\u003c\/td\u003e\n \u003ctd\u003e22 mm\u003c\/td\u003e\n \u003ctd\u003eNormally closed, PNP\u003c\/td\u003e\n \u003ctd\u003eICB30L50N22PCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and installation instructions, please refer to the \u003ca href=\"http:\/\/cga.pub\/?994425\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e","published_at":"2025-08-15T17:29:25+05:30","created_at":"2025-08-15T17:29:26+05:30","vendor":"Waldom Electonics","type":"Sensors\/Transducers","tags":["15MM","CARLO","IMPORT_CSV","IMPORT_PT2","PROX","Proximity","Sensors","Transducers","WLDM"],"price":784979,"price_min":784979,"price_max":784979,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":50623276482877,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ICB30L50F15PO","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ICB30L50F15PO","public_title":null,"options":["Default Title"],"price":784979,"weight":250,"compare_at_price":null,"inventory_management":"shopify","barcode":"ICB30L50F15PO","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/thinkrobotics.com\/cdn\/shop\/files\/50926516.png?v=1755259166"],"featured_image":"\/\/thinkrobotics.com\/cdn\/shop\/files\/50926516.png?v=1755259166","options":["Title"],"media":[{"alt":null,"id":45853400760637,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/50926516.png?v=1755259166"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/thinkrobotics.com\/cdn\/shop\/files\/50926516.png?v=1755259166","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCARLO GAVAZZI ICB30L50F15PO Inductive Proximity Sensor - 15mm Sensing Distance\u003c\/h3\u003e\n\n\u003cp\u003eEnhance your industrial automation with the CARLO GAVAZZI ICB30L50F15PO inductive proximity sensor, designed for precise object detection in demanding environments. Manufactured in LT (Lithuania), this sensor offers reliable performance with a sensing distance of 15mm, extendable up to 22mm, making it ideal for applications requiring high sensing range.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n \u003cli\u003eType: Inductive proximity sensor with nickel-plated brass housing for durability\u003c\/li\u003e\n \u003cli\u003eSensing distance: 15 to 22 mm, suitable for various industrial applications\u003c\/li\u003e\n \u003cli\u003eHousing: Extended length (long body) with options for flush or non-flush mounting\u003c\/li\u003e\n \u003cli\u003eOutput: DC 200 mA, available in NPN or PNP configurations\u003c\/li\u003e\n \u003cli\u003eOutput Mode: Normally open (NO) or Normally closed (NC)\u003c\/li\u003e\n \u003cli\u003ePower supply: Rated operational voltage of 10 - 36 VDC\u003c\/li\u003e\n \u003cli\u003eIndicators: LED for output ON, short-circuit, and overload status\u003c\/li\u003e\n \u003cli\u003eProtection: Reverse polarity, short circuit, and transient protection\u003c\/li\u003e\n \u003cli\u003eConnection options: Cable or M12 plug versions\u003c\/li\u003e\n \u003cli\u003eCompliance: According to IEC 60947-5-2, CSA certified for Hazardous Locations\u003c\/li\u003e\n \u003cli\u003ePackage: Box\u003c\/li\u003e\n \u003cli\u003ePart Number: ICB30L50F15PO\u003c\/li\u003e\n \u003cli\u003eManufacturer: CARLO GAVAZZI\u003c\/li\u003e\n \u003cli\u003eCountry of Origin: LT\u003c\/li\u003e\n \u003cli\u003eUOM: EA\u003c\/li\u003e\n \u003cli\u003eECCN: EAR99\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eParameter\u003c\/th\u003e\n \u003cth\u003eDetails\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eSensing Distance\u003c\/td\u003e\n \u003ctd\u003e15 to 22 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eRated Operating Voltage (Ub)\u003c\/td\u003e\n \u003ctd\u003e10 - 36 VDC\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Current\u003c\/td\u003e\n \u003ctd\u003eDC 200 mA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Type\u003c\/td\u003e\n \u003ctd\u003eNPN or PNP\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eOutput Mode\u003c\/td\u003e\n \u003ctd\u003eNormally open or normally closed\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eHousing Material\u003c\/td\u003e\n \u003ctd\u003eNickel-plated brass\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eProtection Features\u003c\/td\u003e\n \u003ctd\u003eReverse polarity, short circuit, transient\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions \u0026amp; Installation\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eDimension\u003c\/th\u003e\n \u003cth\u003eSize (mm)\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBody Length\u003c\/td\u003e\n \u003ctd\u003e50 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eDiameter\u003c\/td\u003e\n \u003ctd\u003e30 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eAdditional Dimensions\u003c\/td\u003e\n \u003ctd\u003e12 mm, 10.6 mm, 50 mm, 12 mm, 30 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWiring \u0026amp; Mounting\u003c\/h3\u003e\n\u003cp\u003eRefer to the wiring diagram for proper connection. Installation guidelines include considerations for flush or non-flush mounting, with minimum spacing of 6 x sensing distance when sensors are installed opposite each other.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Options\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n \u003cth\u003eConnection Type\u003c\/th\u003e\n \u003cth\u003eSensing Distance\u003c\/th\u003e\n \u003cth\u003eConfiguration\u003c\/th\u003e\n \u003cth\u003ePart Number\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e15 mm\u003c\/td\u003e\n \u003ctd\u003eNormally open, NPN\u003c\/td\u003e\n \u003ctd\u003eICB30S30F15NO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eCable Short\u003c\/td\u003e\n \u003ctd\u003e22 mm\u003c\/td\u003e\n \u003ctd\u003eNormally open, PNP\u003c\/td\u003e\n \u003ctd\u003eICB30S30N22PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003ePlug Short\u003c\/td\u003e\n \u003ctd\u003e15 mm\u003c\/td\u003e\n \u003ctd\u003eNormally closed, NPN\u003c\/td\u003e\n \u003ctd\u003eICB30S30F15NCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLong Cable\u003c\/td\u003e\n \u003ctd\u003e15 mm\u003c\/td\u003e\n \u003ctd\u003eNormally open, PNP\u003c\/td\u003e\n \u003ctd\u003eICB30L50F15PO\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eLong Cable\u003c\/td\u003e\n \u003ctd\u003e22 mm\u003c\/td\u003e\n \u003ctd\u003eNormally closed, PNP\u003c\/td\u003e\n \u003ctd\u003eICB30L50N22PCM1\u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cp\u003eFor more detailed specifications and installation instructions, please refer to the \u003ca href=\"http:\/\/cga.pub\/?994425\" target=\"_blank\"\u003edatasheet\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Datasheet was not processed, please search the internet for the part number for more details.\u003c\/p\u003e\u003cbr\u003e"}
Unfortunately I havent tested the 5G, Only difficult part was connecting antennas. But everything is good, by default it runs on Qualcom's QMI mode, Had to switch to MBIM and it works good with Windows. Planning to run with OpenWRT soon.