CARLO GAVAZZI ICB30S30N15PCM1 Inductive Proximity Sensor - 15mm Sensing Distance

Enhance your industrial automation setup with the CARLO GAVAZZI ICB30S30N15PCM1 inductive proximity sensor, designed for reliable detection in demanding environments. This sensor features a nickel-plated brass housing, ensuring durability and high sensing performance for various applications.

Product Features

  • Sensing Distance: 10 to 15 mm, suitable for precise proximity detection
  • Housing Material: Nickel-plated brass for corrosion resistance and robustness
  • Mounting Options: Available in flush or non-flush types, with short or long body versions
  • Electrical Specifications: Rated operational voltage (Ub): 10 - 36 VDC
  • Output Types: DC 200 mA, NPN or PNP, normally open or normally closed configurations
  • Indication: LED indicators for output ON, short-circuit, and overload conditions
  • Protection Features: Reverse polarity, short circuit, and transient protection
  • Connection Options: Cable or M12 plug versions available
  • Standards Compliance: According to IEC 60947-5-2
  • Certification: CSA certified for Hazardous Locations
  • Part Number: ICB30S30N15PCM1

    Manufacturer: CARLO GAVAZZI

    Country of Origin: LT (Lithuania)

    Unit of Measure: Each (EA)

    ECCN: EAR99

    Package Type: Box

    Datasheet

Technical Specifications

Sensing Distance 10 to 15 mm
Rated Operating Voltage (Ub) 10 - 36 VDC
Output Current DC 200 mA
Housing Material Nickel-plated brass
Standards IEC 60947-5-2

Dimensions (mm)

Short Body 30 mm length, 10.6 mm diameter
Long Body 50 mm length, 12 mm diameter

Installation Guidelines

Proper installation is essential for optimal sensor performance. Flush sensors should be installed in damping material according to the specified guidelines, while non-flush sensors require different mounting considerations. Maintain a minimum space of 6 x Sn (nominal sensing distance) when sensors are installed opposite each other.

Wiring and Connection

Wiring diagrams are available to ensure correct electrical connections for NPN or PNP outputs, with options for cable or M12 plug connections.

Additional Information

For more details, refer to the Datasheet. Please note that specifications are subject to change without notice. For further inquiries or custom configurations, contact your supplier.

Note: Datasheet was not processed, please search the internet for the part number for more details.


Our team will contact you with bulk pricing!

Want to buy in bulk?

Meet with our team

Custom Requirements?

Discussion Forum

Welcome to the discussion thread for ICB30S30N15PCM1
Feel free to ask questions, share tips or report issues.